Effect of geometry and scale for axial and radial flow membrane chromatography-Experimental study of bovin serum albumin adsorption.

J Chromatogr A

Laboratoire d'Automatique et de Génie des Procédés (LAGEP), Université Claude Bernard Lyon I, 43, bd du 11 Novembre 1918, Bâtiment CPE, 69622 Villeurbanne Cedex, France. Electronic address:

Published: July 2015

During the last 10 years, membrane chromatography (MC) has been increasingly reported for biomolecule purification at both small and large scales. Although, several axial and radial flow MC devices are commercialized, the effect of the device dimensions on the adsorption performance has not been fully investigated. In this study, axial and radial flow anion ion-exchange MC devices were used for bovine serum albumin (BSA) adsorption. For both axial and radial flow, three devices at different scales were compared, two having similar diameter and two similar bed height. The pressure drop and the flow distribution using acetone as a non-binding solute were measured, as well as BSA breakthrough curves at different flow rates and BSA loading concentrations. For all devices, it was observed that the flow rate had no effect on the breakthrough curve, which confirms the advantage of MC to be used at high flow rates. In addition, the BSA binding capacity increased with increasing BSA concentration, which suggests that it could be preferable to work with concentrated solutions rather than with very dilute solutions, when using buffer at high phosphate concentration. For both axial and radial flow, the bed height had a negative impact on the binding capacity, as the lowest binding capacities per membrane volume were obtained with the devices having the highest bed height. Radial flow MC has potential at large-scale applications, as a short bed thickness can be combined with a large inlet surface area.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2015.05.023DOI Listing

Publication Analysis

Top Keywords

radial flow
24
axial radial
20
bed height
12
flow
10
serum albumin
8
flow rates
8
binding capacity
8
radial
6
axial
5
devices
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!