Field Safety Notes in Product Problems of Medical Devices for Use in Pulmonology.

Adv Exp Med Biol

c/o Prof. Dr. Schweim; Drug Regulatory Affairs, Pharmaceutical Institute, University Bonn, An der Immenburg 4, 53121, Bonn, Germany,

Published: October 2015

The current European system for medical devices is governed by three EC directives: the Medical Device Directive 93/42/EEC, the In-Vitro Diagnostic Directive 98/79/EC and the Active Implantable Medical Device Directive 90/385/EEC and regulates marketing and post-market surveillance of medical devices in the European Economic Area. In cases of incidents and field safety corrective actions (FSCA) manufacturers have to inform the responsible Competent Authority, which is the Federal Institute for Drugs and Medical Devices (BfArM) and the public by field safety notices (FSN). In this study we analyzed FSN of medical devices exclusively serving for diagnostics or treatment in pulmonology (e.g. nebulizers, oxygen concentrators, pulse oximeters, lung function analyzers, and non-active devices for treatment). FSCA and FSN publicized by BfArM in 2005-2013 were analyzed in respect to the MEDDEV 2.12-1 rev 8. In total 41 FSCA were publicized for the included products. German and English FSN were found in 36/35 cases, respectively. FSN were clearly characterized as FSN in 22/20 cases and declaration of the type of action was found in 27/26 cases, respectively. Product names were provided in all cases. Lot numbers or other information for product characterization were available in 7/8 and 26/24 cases, respectively. Detailed information regarding FSCA and product malfunction were found in 27/33 and 36/35 cases, respectively. Information on product related risks with previous use of the affected product was provided in 24/23 cases. In 34/34 cases manufacturers provided information to mitigate product related risks. Requests to pass FSN to persons needing awareness were found in 10/14 cases. Contact data were provided in 30/30 cases. Confirmation that the Competent Authority was informed was found in 12/14 cases and in 19/18 cases a customer confirmation was included. The obtained data suggest that there is an increasing annual number of FSCA and most FSN fulfill the criteria of MEDDEV 2.12-1 rev 8. However, there are differences between German and English FSN, e.g. regarding the distribution to persons needing awareness, missing statement that the Competent Authority was informed and missing customer confirmation. Due to the importance of FSN for reduction of product related risks in FSCA type and content of FSN should be further improved.

Download full-text PDF

Source
http://dx.doi.org/10.1007/5584_2015_133DOI Listing

Publication Analysis

Top Keywords

medical devices
20
cases
13
field safety
12
competent authority
12
product risks
12
fsn
11
product
8
medical device
8
device directive
8
fsca fsn
8

Similar Publications

Background: Wound repair methods are commonly used in clinical practice, such as skin graft and flap repair, which can cause secondary injuries, and high costs. Many methods for skin stretching and repair have been reported domestically and internationally. However, their clinical use is limited owing to lack of equipment, complexity, and high costs.

View Article and Find Full Text PDF

Impact of central corneal astigmatism on postoperative visual outcomes in patients undergoing trifocal intraocular lens implantation.

BMC Ophthalmol

January 2025

Department of Ophthalmology, Eye & ENT Hospital, Fudan University, 83 Fenyang Road, Xuhui District, Shanghai, 200031, China.

Background: To investigate the impact of central corneal astigmatism on postoperative visual outcomes in patients with trifocal intraocular lens (IOL) implantation.

Methods: This retrospective study included 278 eyes of 278 patients who underwent uneventful cataract surgery with implantation of the trifocal IOL (AT LISA tri 839MP). Patients were divided into two groups according to the total corneal refractive power (TCRP) in 3 mm zone centered on the corneal apex: low astigmatism group, TCRP ≤ 0.

View Article and Find Full Text PDF

In recent years, the government has promoted the increased deployment of automated external defibrillators (AEDs) in public places with dense crowds, which is of great significance for ensuring that residents enjoy equal health rights. However, it is still unclear what factors decision-makers take into account when formulating deployment plans and whether these factors are related to local characteristics such as population distribution and socioeconomic conditions. Taking Shanghai, China as the research area, we adopted the kernel density estimation and spatial autocorrelation analysis to explore the spatial distribution characteristics of AEDs.

View Article and Find Full Text PDF

Background: Minimally invasive dentistry is now becoming the forefront of restorative dentistry, involving less traumatic treatment protocols, conservation of tooth structure and surrounding tissues, enhancing the long-term survivability of treated teeth, and improving the overall quality of life for patients.

Objective: The current case report was conducted to evaluate acquiring deep subgingival interproximal carious lesions by the mean of thermacut bur gingivectomy, in terms of patient satisfaction through pain evaluation, Bleeding on Probing, Pocket Depth, Crestal Bone Level evaluation, and restoration evaluation using modified USPHS criteria.

Material And Methods: A patient with a deep proximal cavity in the posterior tooth was thoroughly examined and underwent Thermacut Bur Gingivectomy (TBG) after caries removal followed by direct resin composite restoration of the prepared cavity.

View Article and Find Full Text PDF

Short-stem total hip arthroplasty (SHA) has become popular because it preserves femoral bone stock and enables the use of short femoral stems in revision total hip arthroplasty (THA). However, no study has evaluated whether a short stem in revision THA, replacing a standard stem, can provide adequate primary stability to facilitate osseous integration. In this biomechanical study, a metaphyseal anchoring SHA (Tri-Lock BPS) stem and a standard THA (Corail) stem were implanted into ten composite femurs and loaded dynamically from 300 to 1700 N with 1 Hz.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!