Purpose: To compare the measurements of refractive errors and ocular aberrations obtained using iDesign and WaveScan (Abbott Medical Optics, Inc., Santa Ana, CA), and to compare surgical outcomes of wavefront-guided LASEK using ablation profiles based on both aberrometers.

Methods: Ninety myopic eyes of 45 normal patients were evaluated using both the iDesign and WaveScan to measure spherical and cylindrical errors, spherical equivalents, and Zernike coefficients of ocular aberrations. Wavefront-guided LASEK was performed in a different group of 59 eyes of 30 patients divided into two groups, the iDesign and Wavescan groups. The clinical outcomes between the two groups including uncorrected visual acuity, refractive errors, contrast sensitivity, and ocular aberration were compared at 1, 3, and 6 months postoperatively.

Results: The iDesign produced significantly higher myopic values for refractive errors than the WaveScan, as well as significantly lower levels of total higher order, third, fourth, and fifth order root mean square values and Zernike coefficients of vertical coma and spherical aberration. At postoperative 1, 3, and 6 months, there were no statistically significant differences between the two groups in terms of uncorrected visual acuity and remaining refractive errors. The percentages of patients with spherical equivalents within ±1.00 and ±0.50 diopters of emmetropia were 100% (29 eyes) and 75.9% (22 eyes), respectively, in the iDesign group and 96.7% (29 eyes) and 70.0% (21 eyes), respectively, in the WaveScan group. Mesopic contrast sensitivity values were significantly higher, and the change in root mean square values for spherical aberration was significantly lower in the iDesign group.

Conclusions: There were significant differences between the iDesign and the WaveScan in the measurements of refraction and ocular aberrations. Wavefront-guided LASEK based on an ablation profile from the iDesign demonstrated comparable refractive predictability with the WaveScan group, resulting in minimal physician adjustment and superior postoperative visual quality.

Download full-text PDF

Source
http://dx.doi.org/10.3928/1081597X-20150521-06DOI Listing

Publication Analysis

Top Keywords

idesign wavescan
20
wavefront-guided lasek
16
refractive errors
16
ocular aberrations
12
idesign
9
clinical outcomes
8
outcomes wavefront-guided
8
wavescan
8
spherical equivalents
8
zernike coefficients
8

Similar Publications

Purpose: To compare refractive, visual, and patient-reported outcomes associated with a 1st generation wavefront-guided (WFG) treatment with those associated with a 3rd generation WFG treatment.

Patients And Methods: This retrospective study included patients who underwent femtosecond laser-assisted in situ keratomileusis (LASIK) for myopia/myopic astigmatism. Two random stratified samples of patients who underwent either 1stgeneration (WaveScan, Johnson & Johnson Vision, Santa Ana, CA) or 3rd generation (iDesign 2.

View Article and Find Full Text PDF

Wavefront-guided myopic laser in situ keratomileusis with a high-resolution Hartmann-Shack aberrometer and a new nomogram.

J Cataract Refract Surg

July 2021

From the Maloney-Shamie Vision Institute, Los Angeles, California (Maloney); Kraff Eye Institute, Chicago, Illinois (Kraff); Coleman Vision, Albuquerque, New Mexico (Coleman).

Purpose: To evaluate visual, refractive, aberrometric, and patient-reported outcomes of wavefront-guided (WFG) myopic laser in situ keratomileusis (LASIK) using a high-resolution Hartmann-Shack aberrometer (iDesign Advanced WaveScan system) with a new nomogram and to determine whether the new nomogram resolved the mild undercorrection that occurs with the manufacturer's default settings.

Setting: Three private LASIK practices.

Design: Prospective, open-label, noncomparative, multicenter study.

View Article and Find Full Text PDF

Purpose: To compare and analyze the differences in visual outcomes between Visx iDesign Advanced WaveScan Studio™ System, Alcon Wavelight Allegro Topolyzer and Nidek EC-5000 using Final Fit™ Custom Ablation Treatment Software from the submitted summary of safety and effectiveness of the US Food and Drug Administration (FDA) data.

Methods: In this retrospective comparative study, 334 eyes from Visx iDesign, 212 eyes from Alcon Contour, and 135 eyes from Nidek CATz platforms were analyzed for primary and secondary visual outcomes. These outcomes were compared via side-by-side graphical and tabular representation of the FDA data.

View Article and Find Full Text PDF

Purpose: To evaluate and compare visual and refractive outcomes after laser-assisted in situ keratomileusis (LASIK) surgery for the correction of myopia or myopic astigmatism using 3 different treatment protocols.

Methods: We included 736 eyes of 369 patients (age 18-62 years) divided into 3 groups: 235 eyes of 118 patients (MEL80 group) undergoing LASIK using optimized aspheric ablation profiles (MEL80 excimer laser; Carl Zeiss Meditec), 248 eyes of 124 patients (Wavescan group) undergoing wavefront-guided (WFG) LASIK (STAR S4IR excimer laser + Wavescan aberrometer; Abbott Medical Optics), and 253 eyes of 127 patients (iDesign group) undergoing WFG LASIK (STAR S4IR excimer laser + iDesign system; Abbott Medical Optics). Visual and refractive outcomes were evaluated 2 months after surgery.

View Article and Find Full Text PDF

Outcomes of wavefront-guided laser in situ keratomileusis using a new-generation Hartmann-Shack aberrometer in patients with high myopia.

J Cataract Refract Surg

September 2015

From the Department of Ophthalmology (Schallhorn), University of California, San Francisco, California, USA; Optical Express (Schallhorn, Venter, Hannan, Hettinger), Glasgow, United Kingdom.

Purpose: To evaluate refractive and visual outcomes of wavefront-guided laser in situ keratomileusis (LASIK) to correct high myopia using a new Hartmann-Shack aberrometer.

Setting: Optical Express, Glasgow, United Kingdom.

Design: Retrospective noncomparative case series.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!