Analysis of EPA's endocrine screening battery and recommendations for further review.

Regul Toxicol Pharmacol

Center for Environmental and Human Toxicology, College of Veterinary Medicine, University of Florida, Gainesville, FL, USA; Applied Pharmacology and Toxicology, Inc., Gainesville, FL, USA.

Published: August 2015

EPA's Endocrine Disruptor Screening Program Tier 1 battery consists of eleven assays intended to identify the potential of a chemical to interact with the estrogen, androgen, thyroid, or steroidogenesis systems. We have collected control data from a subset of test order recipients from the first round of screening. The analysis undertaken herein demonstrates that the EPA should review all testing methods prior to issuing further test orders. Given the frequency with which certain performance criteria were violated, a primary focus of that review should consider adjustments to these standards to better reflect biological variability. A second focus should be to provide detailed, assay-specific direction on when results should be discarded; no clear guidance exists on the degree to which assays need to be re-run for failing to meet performance criteria. A third focus should be to identify permissible differences in study design and execution that have a large influence on endpoint variance. Experimental guidelines could then be re-defined such that endpoint variances are reduced and performance criteria are violated less frequently. It must be emphasized that because we were restricted to a subset (approximately half) of the control data, our analyses serve only as examples to underscore the importance of a detailed, rigorous, and comprehensive evaluation of the performance of the battery.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.yrtph.2015.05.028DOI Listing

Publication Analysis

Top Keywords

performance criteria
12
epa's endocrine
8
control data
8
criteria violated
8
analysis epa's
4
endocrine screening
4
screening battery
4
battery recommendations
4
recommendations review
4
review epa's
4

Similar Publications

Purpose: The aim of the study was to investigate the value of SwiftScan Step-and-Shoot Continuous (SSC) scanning mode in enhancing image quality and to explore appropriate scanning parameters for reducing scan time.

Methods: This study was composed of a phantom study and two clinical tests. The differences in visual image quality scores, coefficient of variance (COV) of the background, image signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and recovery coefficient (RC) of the sphere were compared between SSC mode and traditional Step-and-Shoot (SS) mode in the phantom study.

View Article and Find Full Text PDF

Purpose: The main objective of this study was to conduct a radioanatomical study of the osteo-myo-cutaneous scapulo-dorsal pedicled flap.

Methods: A radiological study was performed to study the anatomical variations of the dorsal scapular pedicle (origin, course of the deep branch of the dorsal scapular artery (DSA) in relation to the medial border of the scapula, perforators from the superficial branch of the DSA). Perforators from the superficial branch of the DSA were also identified on anatomical subjects, and their cutaneous vascular territory was determined.

View Article and Find Full Text PDF

Exploring the potential of the combined diagnostic model of ADC value and bp-MRI VI-RADS in the evaluation of muscle invasion in bladder Cancer.

Abdom Radiol (NY)

January 2025

Department of Radiology, Shengli Clinical Medical College of Fujian Medical University, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, Fuzhou, China.

Objective: This study investigates the diagnostic value of Vesical Imaging Reporting and Data System (VI-RADS) in biparametric MRI (bp-MRI) for the detection of muscular infiltration in bladder cancer, and to investigate whether apparent diffusion coefficient (ADC) value can function as a potential indicator of bp-MRI VI-RADS for patient benefit.

Materials And Methods: This single-center retrospective study enrolled 81 patients with pathologically confirmed bladder cancer from October 2019 to November 2021. Two readers independently scored the T2-weighted images and diffusion-weighted images of each index lesion based on the VI-RADS criteria, subsequently deriving the bp-MRI VI-RADS scores.

View Article and Find Full Text PDF

Unlabelled: The performance of the Liofilchem Compact Antimicrobial Susceptibility Panel (ComASP) Cefiderocol was evaluated in a multicenter study. Enterobacterales, , and clinical isolates and challenge isolates were tested by three and one sites, respectively. Minimum inhibitory concentration (MIC) testing was performed by the Clinical and Laboratory Standards Institute (CLSI) broth microdilution and ComASP, which included two reading endpoints (CLSI read; MIC is the first well in which reduction of growth is <1 mm or light haze/faint turbidity] and ComASP [ComASP read; MIC is the first well at which 100% inhibition of growth occurs]).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!