Purpose: [(18)F]FPEB is a promising PET radioligand for the metabotropic glutamate receptor 5 (mGluR5), a potential target for the treatment of neuropsychiatric diseases. The purpose of this study was to evaluate the test-retest reproducibility of [(18)F]FPEB in the human brain.
Methods: Seven healthy male subjects were scanned twice, 3 - 11 weeks apart. Dynamic data were acquired using bolus plus infusion of 162 ± 32 MBq [(18)F]FPEB. Four methods were used to estimate volume of distribution (V T): equilibrium analysis (EQ) using arterial (EQA) or venous input data (EQV), MA1, and a two-tissue compartment model (2 T). Binding potential (BP ND) was also estimated using cerebellar white matter (CWM) or gray matter (CGM) as the reference region using EQ, 2 T and MA1. Absolute test-retest variability (aTRV) of V T and BP ND were calculated for each method. Venous blood measurements (C V) were compared with arterial input (C A) to examine their usability in EQ analysis.
Results: Regional V T estimated by the four methods displayed a high degree of agreement (r (2) ranging from 0.83 to 0.99 among the methods), although EQA and EQV overestimated V T by a mean of 9 % and 7 %, respectively, compared to 2 T. Mean values of aTRV of V T were 11 % by EQA, 12 % by EQV, 14 % by MA1 and 14 % by 2 T. Regional BP ND also agreed well among the methods and mean aTRV of BP ND was 8 - 12 % (CWM) and 7 - 9 % (CGM). Venous and arterial blood concentrations of [(18)F]FPEB were well matched during equilibrium (C V = 1.01 · C A, r (2) = 0.95).
Conclusion: [(18)F]FPEB binding shows good TRV with minor differences among analysis methods. Venous blood can be used as an alternative for input function measurement instead of arterial blood in EQ analysis. Thus, [(18)F]FPEB is an excellent PET imaging tracer for mGluR5 in humans.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5467218 | PMC |
http://dx.doi.org/10.1007/s00259-015-3094-6 | DOI Listing |
Int J Older People Nurs
January 2025
School of Nursing, Shandong University of Traditional Chinese Medicine, Jinan, Shandong, China.
Aim: To translate the 9-item Confidence in Dementia (CODE) scale into Chinese (Confidence in Dementia-Chinese, CODE-C) and evaluate its psychometric properties among clinical nurses.
Background: With the rapidly ageing population, an increasing number of patients with dementia will be cared for in hospitals. Clinical nurses' confidence in dementia care is crucial to provide quality care.
Skelet Muscle
December 2024
Rehabilitation Sciences Institute, University of Toronto, Toronto, ON, Canada.
Background: INTER- and INTRAmuscular fat (IMF) is elevated in high metabolic states and can promote inflammation. While magnetic resonance imaging (MRI) excels in depicting IMF, the lack of reproducible tools prevents the ability to measure change and track intervention success.
Methods: We detail an open-source fully-automated iterative threshold-seeking algorithm (ITSA) for segmenting IMF from T1-weighted MRI of the calf and thigh within three cohorts (CaMos Hamilton (N = 54), AMBERS (N = 280), OAI (N = 105)) selecting adults 45-85 years of age.
Menopause
January 2025
From the Department of Quality Control, Yuebei People's Hospital, Shantou University Medical College, Shaoguan, China.
Objective: The aim of this study was to modify the Chinese version of the Menopause Symptom Assessment Scale (MSAS) and evaluate its validity and reliability.
Methods: An expert panel from the gynecology and nursing domain determined items that should remain or be revised, and 30 participants were selected for the pilot study. A total of 255 women who met the criteria for inclusion were enrolled in the investigation.
J Funct Morphol Kinesiol
December 2024
University Center for Prevention and Sports Medicine, Balgrist University Hospital, University of Zurich, CH-8008 Zurich, Switzerland.
Grip strength is widely used as a surrogate parameter for functional status. The current gold standard, the JAMAR Hydraulic Dynamometer (JAMAR Hydraulic), presents challenges for individuals with painful finger joints or low grip strength. Therefore, the objective of this observational study was to assess comparability across the JAMAR Smart, the Martin Vigorimeter and the gold standard.
View Article and Find Full Text PDFJ Funct Morphol Kinesiol
December 2024
Escuela de Ciencias de la Actividad Física, El Deporte y la Salud, Facultad de Ciencias Médicas, Universidad de Santiago de Chile, Santiago 8370003, Chile.
Assessing the reliability of measurement instruments and equipment is essential to ensure the accurate tracking of athletes over extended periods, minimizing the measurement errors caused by chance or other factors. However, a less common but equally important analysis is the verification of inter-measurement agreement, which complements the reliability results. To evaluate the intra- and inter-test reliability of an isometric hip adduction strength and asymmetries test in professional soccer players.