A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Measuring tibial component rotation of TKA in MRI: What is reproducible? | LitMetric

Measuring tibial component rotation of TKA in MRI: What is reproducible?

Knee

Sporthopaedicum Straubing, Bahnhofplatz 27, 94315 Straubing, Germany. Electronic address:

Published: December 2015

Purpose: Correct rotational alignment of components is crucial for the success of total knee arthroplasty (TKA). Defining landmarks on the tibia that allow for reproducible measurement of component rotation seems to be more challenging than on the femoral side. This study compares the reproducibility of three different measurement techniques.

Scope: A magnetic resonance imaging (MRI) analysis of 55 patients following TKA was conducted. The rotation of the tibial components was determined using three different reference lines: a tangent to the posterior tibial margin, the tibial epicondylar axis, and the tibial tubercle. Data were analyzed for intra- and inter-observer reliability using intra-class correlation coefficients (ICCs), and a variance comparison between measurement techniques via F-test.

Results: Highest reliability and lowest variances for measurement of tibial component rotation were achieved by relation to the tibial epicondylar axis and posterior tibial margin. The tibial tubercle proved to be less reliable (ICC 0.632 (interobserver) and 0.526 (intraobserver)), and variances were significantly higher in comparison with the other two techniques.

Conclusion: Based on the presented MRI data, measurements of the tibial component rotation are done best using the posterior tibial margin and the tibial epicondylar axis. The tibial tubercle measurement proved to be less reliable for this purpose. We suggest that all three reference lines will be used for assessment of a painful knee following TKA to allow for informed decision making and for choice of best treatment options for the patient.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.knee.2015.01.009DOI Listing

Publication Analysis

Top Keywords

component rotation
16
tibial component
12
tibial
12
posterior tibial
12
tibial margin
12
margin tibial
12
tibial epicondylar
12
epicondylar axis
12
tibial tubercle
12
three reference
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!