Chimeric peptides as implant functionalization agents for titanium alloy implants with antimicrobial properties.

JOM (1989)

Department of Mechanical Engineering and Bioengineering Research Center, University of Kansas, Lawrence, KS-66045 , + 7858642984.

Published: April 2015

Implant-associated infections can have severe effects on the longevity of implant devices and they also represent a major cause of implant failures. Treating these infections associated with implants by antibiotics is not always an effective strategy due to poor penetration rates of antibiotics into biofilms. Additionally, emerging antibiotic resistance poses serious concerns. There is an urge to develop effective antibacterial surfaces that prevent bacterial adhesion and proliferation. A novel class of bacterial therapeutic agents, known as antimicrobial peptides (AMP's), are receiving increasing attention as an unconventional option to treat septic infection, partly due to their capacity to stimulate innate immune responses and for the difficulty of microorganisms to develop resistance towards them. While host- and bacterial- cells compete in determining the ultimate fate of the implant, functionalization of implant surfaces with antimicrobial peptides can shift the balance and prevent implant infections. In the present study, we developed a novel chimeric peptide to functionalize the implant material surface. The chimeric peptide simultaneously presents two functionalities, with one domain binding to a titanium alloy implant surface through a titanium-binding domain while the other domain displays an antimicrobial property. This approach gains strength through control over the bio-material interfaces, a property built upon molecular recognition and self-assembly through a titanium alloy binding domain in the chimeric peptide. The efficiency of chimeric peptide both in-solution and absorbed onto titanium alloy surface was evaluated against three common human host infectious bacteria, , and . In biological interactions such as occurs on implants, it is the surface and the interface that dictate the ultimate outcome. Controlling the implant surface by creating an interface composed chimeric peptides may therefore open up new possibilities to cover the implant site and tailor it to a desirable bioactivity.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4450091PMC
http://dx.doi.org/10.1007/s11837-015-1350-7DOI Listing

Publication Analysis

Top Keywords

titanium alloy
16
chimeric peptide
16
implant
10
chimeric peptides
8
implant functionalization
8
antimicrobial peptides
8
implant surface
8
chimeric
6
surface
5
peptides implant
4

Similar Publications

Antibacterial and Anti-Inflammation Activity of Titanium Alloy by Efficient Copper Immobilization.

Langmuir

January 2025

Department of Biomaterials, Faculty of Dental Science, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.

Titanium alloy plates are often used for fixation to bone. However, the plates often need to be removed due to infection and adverse inflammation. To avoid these problems, we immobilized copper, which has antibacterial effects and low cytotoxicity, on titanium plates by immersing the titanium in copper-tris(hydroxymethyl)aminomethane complex solutions.

View Article and Find Full Text PDF

Hydroxyapatite (HAP) nano-coatings on titanium alloys (for example, Ti6Al4V) have been used for prosthetic orthopedic implants in recent decades due to their osseointegration, bioactivity, and biocompatibility. HAP is brittle with low mechanical strength and poor adhesion on metallic surfaces, which limits its durability and bioactivity. Surface modification techniques have alleviated the imperfection of biomaterials by coating the substrate.

View Article and Find Full Text PDF

The potential of hydrogen plasma arc technology for the efficient deoxygenation and recycling of titanium alloy scrap is explored. The results of thermodynamic analysis reveal that hydrogen plasma is suitable for oxygen removal. The intermediate stages of the deoxygenation process are sequentially analyzed, showing that the hydrogen plasma arc primarily facilitated the reduction and dissolution of oxides as well as eliminated interstitial oxygen.

View Article and Find Full Text PDF

Researchers have modified PLA materials to enhance their mechanical properties and meet the clinical requirements. However, the strength and stiffness of PLA are still significantly lower than those of metals. Building on the established chevron clinical procedure and considering the mechanical characteristics of PLA screws, we devised a modified chevron osteotomy (MCO) based on a load-reducing structure with the aim of reducing the load on the screws.

View Article and Find Full Text PDF

Titanium alloys are widely used in the manufacture of orthopedic prosthesis given their excellent mechanical properties and biocompatibility. However, the primary drawbacks of traditional titanium alloy prosthesis are their much higher elastic modulus than cancellous bone and poor interfacial adhesion, which lead to poor osseointegration. 3D-printed porous titanium alloys can partly address these issues, but their bio-inertness still requires modifications to adapt to different physiological and pathological microenvironments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!