Background: Accurate measurement of free-living energy intake (EI) over long periods is imperative for understanding obesity and its treatment. Unfortunately, traditional methods rely on self-report and are notoriously inaccurate. Although EI can be indirectly estimated by the intake-balance method, this technique is prohibitively labor-intensive and expensive, requiring repeated measures of energy expenditure via doubly labeled water (DLW) along with multiple dual-energy X-ray absorptiometry (DXA) scans to measure changes in body energy stores.
Objective: Our objective was to validate a mathematical method to measure long-term changes in free-living energy intake.
Design: We measured body weight and EI changes (ΔEI) over 4 time intervals by using the intake-balance method in 140 individuals who underwent 2 y of caloric restriction as part of the Comprehensive Assessment of Long-term Effects of Reducing Intake of Energy study. We compared the ΔEI values calculated by using DLW/DXA with those obtained by using a mathematical model of human metabolism whose only inputs were the initial demographic information and repeated body weight data.
Results: The mean ΔEI values calculated by the model were within 40 kcal/d of the DLW/DXA method throughout the 2-y study. For individual subjects, the overall root mean square deviation between the model and DLW/DXA method was 215 kcal/d, and most of the model-calculated ΔEI values were within 132 kcal/d of the DLW/DXA method.
Conclusions: Accurate and inexpensive estimates of ΔEI that are comparable to the DLW/DXA method can be obtained by using a mathematical model and repeated body weight measurements.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4515869 | PMC |
http://dx.doi.org/10.3945/ajcn.115.111070 | DOI Listing |
Med Sci Sports Exerc
January 2025
Energy Metabolism Section, National Institute of Diabetes, Digestive and Kidney Diseases, Diabetes, Endocrinology, and Obesity Branch, National Institutes of Health (NIH), Bethesda, MD.
Introduction: ActiGraph accelerometers are used extensively to objectively assess physical activity, sedentary behavior, and sleep. Here, we present an objective validation of five generations of ActiGraph sensors to characterize potential differences in output arising from changes to hardware or firmware.
Methods: An orbital shaker generated accelerations from 0 to 3700 milli-g in a randomized order to test the wGT3X-BT, GT9X, CentrePoint Insight Watch (CPIW) 1.
Proc Nutr Soc
January 2025
Department of Nutritional Sciences, Faculty of Health and Medical Science, University of Surrey, Guildford, SurreyGU2 7XH, UK.
The potential influence of the timing of eating on body weight regulation in humans has attracted substantial research interest. This review aims to critically evaluate the evidence on timed eating for weight loss, considering energetic and behavioural components of the timing of eating in humans. It has been hypothesised that timed eating interventions may alter energy balance in favour of weight loss by enhancing energy expenditure, specifically the thermic effect of food.
View Article and Find Full Text PDFAppl Environ Microbiol
January 2025
Department of Biological Sciences, Clemson University, Clemson, South Carolina, USA.
Unlabelled: The abundant and metabolically versatile aquatic bacterial order, , influences marine biogeochemical cycles. We assessed metagenome-assembled genome (MAG) abundance, estimated growth rates, and potential and expressed functions in the Chesapeake and Delaware Bays, two important US estuaries. Phylogenomics of draft and draft/closed genomes from this study and others placed 46 nearly complete MAGs from these bays into 11 genera, many were not well characterized.
View Article and Find Full Text PDFJMIR Form Res
December 2024
Department of Sports Science, College of Education, Zhejiang University, No. 866, Yuhangtang Road, Hangzhou, 310030, China, 86 18667127699.
Background: Smartwatches are increasingly popular for physical activity and health promotion. However, ongoing validation studies on commercial smartwatches are still needed to ensure their accuracy in assessing daily activity levels, which is important for both promoting activity-related health behaviors and serving research purposes.
Objective: This study aimed to evaluate the accuracy of a popular smartwatch, the Huawei Watch GT2, in measuring step count (SC), total daily activity energy expenditure (TDAEE), and total sleep time (TST) during daily activities among Chinese adults, and test whether there are population differences.
Appl Environ Microbiol
December 2024
Hubei Key Laboratory of Multi-media Pollution Cooperative Control in Yangtze Basin, School of Environmental Science and Engineering, Huazhong University of Science and Technology, Wuhan, China.
Unlabelled: During the coronavirus disease 2019 epidemic, excessive chlorine disinfectants have been used to block the spread of severe acute respiratory syndrome-coronavirus 2, resulting in large amounts of residual disinfectants entering wastewater treatment plants (WWTPs) through sewage systems. So far, no relevant research has been conducted on the impact of chlorine disinfectants on microfauna, an important microbial component in activated sludge treatment systems. This study comprehensively investigated the changes in microfauna habitat, community structure, and colonization mode under the chlorine stress by combining the full-scale WWTP survey and laboratory-scale sequencing batch reactor experiments.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!