Objective: To compare foam bubble size and bubble size distribution, stability, and degradation rate of commercially available polidocanol endovenous microfoam (Varithena®) and physician-compounded foams using a number of laboratory tests.

Methods: Foam properties of polidocanol endovenous microfoam and physician-compounded foams were measured and compared using a glass-plate method and a Sympatec QICPIC image analysis method to measure bubble size and bubble size distribution, Turbiscan™ LAB for foam half time and drainage and a novel biomimetic vein model to measure foam stability. Physician-compounded foams composed of polidocanol and room air, CO2, or mixtures of oxygen and carbon dioxide (O2:CO2) were generated by different methods.

Results: Polidocanol endovenous microfoam was found to have a narrow bubble size distribution with no large (>500 µm) bubbles. Physician-compounded foams made with the Tessari method had broader bubble size distribution and large bubbles, which have an impact on foam stability. Polidocanol endovenous microfoam had a lower degradation rate than any physician-compounded foams, including foams made using room air (p < 0.035). The same result was obtained at different liquid to gas ratios (1:4 and 1:7) for physician-compounded foams. In all tests performed, CO2 foams were the least stable and different O2:CO2 mixtures had intermediate performance. In the biomimetic vein model, polidocanol endovenous microfoam had the slowest degradation rate and longest calculated dwell time, which represents the length of time the foam is in contact with the vein, almost twice that of physician-compounded foams using room air and eight times better than physician-compounded foams prepared using equivalent gas mixes.

Conclusion: Bubble size, bubble size distribution and stability of various sclerosing foam formulations show that polidocanol endovenous microfoam results in better overall performance compared with physician-compounded foams. Polidocanol endovenous microfoam offers better stability and cohesive properties in a biomimetic vein model compared to physician-compounded foams. Polidocanol endovenous microfoam, which is indicated in the United States for treatment of great saphenous vein system incompetence, provides clinicians with a consistent product with enhanced handling properties.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4838175PMC
http://dx.doi.org/10.1177/0268355515589063DOI Listing

Publication Analysis

Top Keywords

physician-compounded foams
24
bubble size
24
polidocanol endovenous
20
endovenous microfoam
20
size distribution
16
microfoam varithena®
8
size bubble
8
degradation rate
8
foam stability
8
room air
8

Similar Publications

Low temperature offers better foam stability.

J Cosmet Dermatol

October 2024

Department of Cardiovascular Surgery, Ankara City Hospital, Ankara, Turkey.

Background: The foam's structural longevity, linked to the effectiveness of sclerotherapy, depends on preparation conditions. The factors enhancing the treatment's effectiveness and efficacy are still under discussion.

Methods: We conducted an in vitro preclinical research, which included 144 independent trials.

View Article and Find Full Text PDF

Loss of vision after topical injection of sclerosant is a rare and uncommon complication. We describe a case with vision loss following the facial injections of physician-compounded (PCP) foam sclerotherapy which was created by room air. A 3-year-old boy underwent injection of 5ml polidocanol foamed with room air to treat the venous malformation on the cheek near the left orbit.

View Article and Find Full Text PDF

Sclerotherapy is among the least invasive and most commonly utilised treatment options for varicose veins. Nonetheless, it does not cure varicosities permanently and recurrence rates are of up to 64%. Although sclerosing foams have been extensively characterised with respect to their bench-top properties, such as bubble size distribution and half-life, little is known about their flow behaviour within the venous environment during treatment.

View Article and Find Full Text PDF

Since the first reports on foam sclerotherapy, multiple studies have been conducted to determine the physical properties and behavior of foams, but relatively little is known about their biological effects on the endothelial cells lining the vessel wall. Moreover, a systematic comparison of the biological performance of foams produced with different methods has not been carried out yet. Herein, a 2D in vitro method was developed to compare efficacy of commercially available polidocanol injectable foam (PEM, Varithena) and physician-compounded foams (PCFs).

View Article and Find Full Text PDF

Physical Vein Models to Quantify the Flow Performance of Sclerosing Foams.

Front Bioeng Biotechnol

May 2019

Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, United Kingdom.

Foam sclerotherapy is clinically employed to treat varicose veins. It involves intravenous injection of foamed surfactant agents causing endothelial wall damage and vessel shrinkage, leading to subsequent neovascularization. Foam production methods used clinically include manual techniques, such as the Double Syringe System (DSS) and Tessari (TSS) methods.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!