Objectives: We studied the trends and predictors of drug eluting stent (DES) utilization from 2006 to 2011 to further expound the inter-hospital variability in their utilization.
Background: We queried the Healthcare Cost and Utilization Project's Nationwide Inpatient Sample (NIS) between 2006 and 2011 using ICD-9-CM procedure code, 36.06 (bare metal stent) or 36.07 (drug eluting stents) for Percutaneous Coronary Intervention (PCI). Annual hospital volume was calculated using unique identification numbers and divided into quartiles for analysis.
Methods And Results: We built a hierarchical two level model adjusted for multiple confounding factors, with hospital ID incorporated as random effects in the model. About 665,804 procedures (weighted n = 3,277,884) were analyzed. Safety concerns arising in 2006 reduced utilization DES from 90% of all PCIs performed in 2006 to a nadir of 69% in 2008 followed by increase (76% of all stents in 2009) and plateau (75% in 2011). Significant between-hospital variation was noted in DES utilization irrespective of patient or hospital characteristics. Independent patient level predictors of DES were (OR, 95% CI, P-value) age (0.99, 0.98-0.99, <0.001), female(1.12, 1.09-1.15, <0.001), acute myocardial infarction(0.75, 0.71-0.79, <0.001), shock (0.53, 0.49-0.58, <0.001), Charlson Co-morbidity index (0.81,0.77-0.86, <0.001), private insurance/HMO (1.27, 1.20-1.34, <0.001), and elective admission (1.16, 1.05-1.29, <0.001). Highest quartile hospital (1.64, 1.25-2.16, <0.001) volume was associated with higher DES placement.
Conclusion: There is significant between-hospital variation in DES utilization and a higher annual hospital volume is associated with higher utilization rate of DES. © 2015 Wiley Periodicals, Inc.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ccd.25977 | DOI Listing |
J Cardiothorac Surg
January 2025
The First Department of Cardiology, Beidahuang Industry Group General Hospital, Harbin, 150000, Heilongjiang Province, China.
Objective: it was to evaluate the efficacy and safety of rapamycin-eluting stents at different doses in the treatment of coronary artery narrowing in miniature pigs.
Methods: a total of 20 miniature pigs were randomly assigned into four groups: S1 group (low-dose rapamycin-coated stent, 55 µg/mm), S2 group (medium-dose rapamycin-coated stent, 120 µg/mm), S3 group (high-dose rapamycin-coated stent, 415 µg/mm), and D0 group (bare metal stent). The stent size was 3.
Biomed Eng Online
January 2025
Northwest Institute of Plateau Biology, Chinese Academy of Sciences, Xining, 810008, China.
Recently, the incidence rate and mortality of various acute or chronic vascular occlusive diseases have increased yearly. As one of the most effective measures to treat them, vascular stents have been widely studied by researchers, and presently, the most commonly used is a drug-eluting stent, which reduces the process of rapid endothelialization because the drug is not selective. Fortunately, with the discovery and exploration of micro-nanostructures that can regulate cells selectively, reducing the incidence of "intravascular restenosis" and achieving rapid endothelialization simultaneously are possible through a special structure that cannot only improve endothelial cells (ECs), but also inhibit smooth muscle cells (SMCs).
View Article and Find Full Text PDFSci Rep
January 2025
Division of Hematology and Oncology, University of California, 1450 3rd Street, San Francisco, CA, 94143, USA.
For individuals at high risk of developing breast cancer, interventions to mitigate this risk include surgical removal of their breasts and ovaries or five years treatment with the anti-estrogen tamoxifen or aromatase inhibitors. We hypothesized that a silicone based anti-estrogen-eluting implant placed within the breast would provide the risk reduction benefit of hormonal therapy, but without the adverse effects that limit compliance. To this end, we demonstrate that when placed adjacent to mammary tissue in the 7,12-dimethylbenz[a]anthracene-induced rat breast cancer model a fulvestrant-eluting implant delays breast cancer with minimal systemic exposure.
View Article and Find Full Text PDFAnalyst
January 2025
Department of Comparative Biomedical Sciences, School of Veterinary Medicine, Louisiana State University, Baton Rouge, LA, 70803, USA.
Various technical methodologies are required to accurately detect substances of different chemical and pharmacological properties in biological samples, which are increasing in number and variety daily. Therefore, laboratories where many samples and different factors are analyzed simultaneously need methods with easy sample preparation, short analysis times and low analysis costs. In this study, the objective was to scan substances susceptible to chemical degradation, amenable to analysis without hydrolysis, and exhibiting short-term stability by employing a straightforward, expeditious, and cost-efficient method.
View Article and Find Full Text PDFEur J Drug Metab Pharmacokinet
January 2025
College of Basic Medicine and Forensic Medicine, Henan University of Science and Technology, Luoyang, 471023, China.
Background And Objective: Total glucosides of paeony (TGP) capsules, tripterygium glycoside tablets (TGT), and celecoxib are commonly used drugs in clinical practice for the treatment of Rheumatoid arthritis (RA). An UPLC-MS/MS method for the analysis of celecoxib in beagle dogs was developed, the herb-drug interactions (HDIs) between TGP and TGT with celecoxib were studied based on pharmacokinetics.
Methods: The method of acetonitrile precipitation was applied to process plasma samples.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!