Objective: Optical coherence tomography images may be distorted by motion artifacts in dynamic imaging, so it may lead to misdiagnosis in clinical diagnosis. Motion artifacts correction has become an urgent issue in optical coherence tomography imaging.

Methods: Firstly, using the improved complex nonlinear diffusion preprocessing filtering reduced the noise of the sequence images, then using the image mass center aligned the distortion data in the Y direction, finally, using the method of deviation average corrected motion artifacts along the Y direction.

Results: After correction, the motion artifacts in the longitudinal 2D images and the 3D image disappeared, the surface of the 2D and the 3D image became more smooth, the structure between layers of the images got clear and distinct, retinal en-face single slice image was sharp, and the fundus tissue structure could be observed.

Conclusion: The algorithm of correction makes the physical structure of the retinal display truly after motion artifacts correction.

Download full-text PDF

Source

Publication Analysis

Top Keywords

motion artifacts
24
artifacts correction
12
optical coherence
12
coherence tomography
12
images image
8
artifacts
6
correction
5
motion
5
[study motion
4
correction algorithm
4

Similar Publications

Motion-Compensated Multishot Pancreatic Diffusion-Weighted Imaging With Deep Learning-Based Denoising.

Invest Radiol

January 2025

From the Department of Radiology, Stanford University, Stanford, CA (K.W., M.J.M., A.M.L., A.B.S., A.J.H., D.B.E., R.L.B.); Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (K.W.); GE HealthCare, Houston, TX (X.W.); GE HealthCare, Boston, MA (A.G.); and GE HealthCare, Menlo Park, CA (P.L.).

Objectives: Pancreatic diffusion-weighted imaging (DWI) has numerous clinical applications, but conventional single-shot methods suffer from off resonance-induced artifacts like distortion and blurring while cardiovascular motion-induced phase inconsistency leads to quantitative errors and signal loss, limiting its utility. Multishot DWI (msDWI) offers reduced image distortion and blurring relative to single-shot methods but increases sensitivity to motion artifacts. Motion-compensated diffusion-encoding gradients (MCGs) reduce motion artifacts and could improve motion robustness of msDWI but come with the cost of extended echo time, further reducing signal.

View Article and Find Full Text PDF

Objective: The detection of arterial pulsating signals at the skin periphery with Photoplethysmography (PPG) are easily distorted by motion artifacts. This work explores the alternatives to the aid of PPG reconstruction with movement sensors (accelerometer and/or gyroscope) which to date have demonstrated the best pulsating signal reconstruction.

Approach: A generative adversarial network with fully connected layers (FC-GAN) is proposed for the reconstruction of distorted PPG signals.

View Article and Find Full Text PDF

The motion of the trabecular meshwork (TM) facilitates the aqueous drainage from the anterior chamber to the venous system, thereby maintaining normal intraocular pressure. As such, characterizing the TM motion is valuable for assessing the functionality of the aqueous outflow system, as demonstrated by previous phase-sensitive optical coherence tomography (OCT) studies. Current methods typically acquire motion from a single cross-sectional plane along the circumference of the anterior chamber.

View Article and Find Full Text PDF

Effectiveness of Data-Driven Gating FDG PET/CT for Abdominal Region.

J Nucl Med Technol

January 2025

Department of Nuclear Medicine, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Tokyo, Japan.

This study aimed to validate the effectiveness of MotionFree (MF) in the abdominal region using 2 different PET/CT scanners to determine how to use MF efficiently. All 198 patients underwent respiratory-gated F-FDG PET/CT with MF. Imaging was performed using Discovery MI (DMI) and Discovery IQ (DIQ) PET/CT scanners, and all data were divided into 2 groups in each category (abdominal: upper and lower abdomen, lesion size, <20 mm and ≥20 mm; scanner group: DMI and DIQ).

View Article and Find Full Text PDF

AECuration: Automated event curation for spike sorting.

J Neural Eng

January 2025

Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, Pennsylvania, 15213, UNITED STATES.

Spike sorting is a commonly used analysis method for identifying single-units and multi-units from extracellular recordings. The extracellular recordings contain a mixture of signal components, such as neural and non-neural events, possibly due to motion and breathing artifacts or electrical interference. Identifying single and multi-unit spikes using a simple threshold-crossing method may lead to uncertainty in differentiating the actual neural spikes from non-neural spikes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!