Activity trackers like Fitbit are used for self-tracking of physical activity by an increasing number of individuals. Comparing physical activity scores with peers can contribute to the desired behavioural change. However, for meaningful social comparison a high inter-device reliability is paramount. This study aimed to determine the inter-device reliability of Fitbit activity trackers in measuring steps. Ten activity trackers (Fitbit Ultra) were worn by a single person (male, 46 years) during eight consecutive days. Inter-device reliability was assessed on three different levels of aggregation (minutes, hours, days) with various methods, including intra-class correlation coefficient (ICC), Bland-Altman plots, limits of agreement (LOA) and Mixed Model Analysis. Results showed that the inter-device reliability of the Fitbit in measuring steps is good at all levels of aggregation (minutes, hours, days), but especially when steps were measured per day. This implies that individuals can reliably compare their daily physical activity scores with peers.

Download full-text PDF

Source
http://dx.doi.org/10.3109/03091902.2015.1050125DOI Listing

Publication Analysis

Top Keywords

inter-device reliability
20
measuring steps
12
activity trackers
12
physical activity
12
fitbit activity
8
trackers fitbit
8
activity scores
8
scores peers
8
reliability fitbit
8
levels aggregation
8

Similar Publications

Background: Human milk electrolytes are known biomarkers of stages of lactation in the first weeks after birth. However, methods for measuring milk electrolytes are available only in laboratory or expert settings. A small handheld milk sensing device (Mylee) capable of determining on-site individual secretory activation progress from sensing the conductivity of a tiny milk specimen was developed.

View Article and Find Full Text PDF

The present study aimed to explore the validity and inter-device reliability of a novel artificial intelligence app (Asstrapp) for real-time measurement of the traditional (tra505) and modified-505 (mod505) change of direction (COD) tests. Twenty-five male Sports Science students (age, 23.5 ± 3.

View Article and Find Full Text PDF

The aim of this retrospective study was to compare corneal parameters and compliance using a Pentacam HR-Scheimpflug (Pentacam HR) and a swept-source OCT Casia (Casia) in keratoconus (KC) patients post penetrating keratoplasty (PKP) and KC patients without PKP, as well as a control group. Pachymetry measurements were also analyzed using a spectral domain OCT Solix (OCT Solix), Pentacam HR, and Casia. The study included 71 patients (136 keratoconic eyes; group A), 86 eyes with KC post-PKP (group B), 50 eyes with KC without PKP (group C), and 52 control participants (104 eyes).

View Article and Find Full Text PDF

This study aimed to analyze the intra-device agreement of a new linear position transducer (Vitruve, VT) and the inter-device agreement with a previously validated linear velocity transducer (T-Force System, TF) in different range of velocities. A group of 50 healthy, physically active men performed a progressive loading test during a bench press (BP) and full-squat (SQ) exercise with a simultaneous recording of two VT and one TF devices. The mean propulsive velocity (MPV) and peak of velocity (PV) were recorded for subsequent analysis.

View Article and Find Full Text PDF
Article Synopsis
  • * Results indicated a strong correlation between the two devices, with high agreement in velocity measurements (r values between 0.96-0.99), and only minor differences at lower weight loads.
  • * Both devices demonstrated excellent reliability, making them effective tools for assessing movement velocity in resistance training for older populations.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!