We want to address the clinical issue of too sparse supply of allograft in total hip replacement and ambitions of controlling the grain size distribution. Bioglass BAG-S53P4 was evaluated as a bone graft additive to chemically treated allografts with controlled grain size distribution. Allografts were chemically cleaned (CG) and mixed with BAG-S53P4 additive (BG) for comparison. All samples were compacted with a dropped weight apparatus and then underwent a uniaxial compression test. The yield limit was determined by a uniaxial compression test and density was recorded while flowability was calculated. There was no difference between the yield stress limit of BG and CG after compaction (p=0.432). Adding BAG-S53P4 reduced flowability and could indicate better interlocking mechanism between particles. Adding BAG-S53P4 seems to have no impact on the yield stress limit. The extended allografts withstand the compaction equally good which makes it a valid bone substitute in total hip replacement. An in vivo loaded study is needed before clinical use can be recommended.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jor.22953 | DOI Listing |
Sci Rep
December 2024
Department of Materials and Metallurgical Engineering, Amirkabir University of Technology, Tehran, 15875-4413, Iran.
This study explores the impact of metallic shells by electroforming method on the mechanical behavior of thermoplastic polyurethane (TPU)-based lattice structures. First, the TPU lattice structures were printed by additive manufacturing technique. Then layers of Ni and Cu as a thin shell were dressed on the TPU lattice structures in the electroforming baths of Ni and Cu solutions.
View Article and Find Full Text PDFSci Rep
December 2024
College of Civil Engineering and Transportation, Hohai University, Nanjing, 210098, China.
The columnar joint skeleton of 3D printed Acrylonitrile Butadiene Styrene (ABS) material, the skeleton of cement mortar and ultraviolet aging treatment are combined to pour the columnar joint rock mass (CJRM) test block. The strength, deformation, energy and failure modes of the specimens with different dip angles were analyzed by uniaxial compression test. The influence of joint skeleton on the strength of the test block was analyzed.
View Article and Find Full Text PDFGels
November 2024
Departamento de Química, Facultad de Ciencias Naturales, Matemáticas y del Medio Ambiente, Universidad Tecnológica Metropolitana, Santiago 7800003, Chile.
The preparation of sophisticated hierarchically structured and cytocompatible hydrogel scaffolds is presented. For this purpose, a photosensitive resin was developed, printability was evaluated, and the optimal conditions for 3D printing were investigated. The design and fabrication by additive manufacturing of tailor-made porous scaffolds were combined with the formation of surface wrinkled micropatterns.
View Article and Find Full Text PDFClin Biomech (Bristol)
December 2024
Department of Kinesiology and Physical Education, Wilfrid Laurier University, Waterloo, Ontario, Canada; Department of Health Sciences, Wilfrid Laurier University, Waterloo, Ontario, Canada. Electronic address:
Background: Vertebral fractures in young populations are associated with intervertebral disc disorders later in life. However, damage to the annulus fibrosus has been observed in rapidly loaded spines even without the subsequent occurrence of a fracture. Therefore, it may not be the fracture event that compromises the disc, but rather the manner in which the disc is loaded.
View Article and Find Full Text PDFHeliyon
December 2024
Department of Mechanical Engineering, Sogang University, Seoul, 04107, Republic of Korea.
Damage models have significantly advanced predictions of ductile fractures in large, thin-walled structures like automobiles, ships, and aircraft. However, accurately predicting these fractures remains challenging due to variations in strain localization, ranging from biaxial compression to tension. This study introduces a specialized damage model for shell elements, utilizing data from shear, uniaxial, and plane tension tests.