Objective: Articular penetration of K-wires is a possible complication of the modified tension band wiring technique. However, there is no clear information or evidence regarding the entry point or introduction angle for K-wires to avoid this complication. The aim of this experimental study was to evaluate the effect of varying K-wire insertion points and angles on the risk for articular penetration during modified tension band wiring for olecranon fractures.

Methods: All anatomical measurements were made on 50 cadaveric ulnas, and all other measurements were performed on exact foam replications of the 50 cadaveric ulnas. Morphometric measurements, including olecranon height and heights of the central, radial and ulnar facets of the semilunar notch, were taken. In the sagittal plane, articular angle and tubercle angle were measured. Two 1.6-mm parallel K-wires were inserted from 0, 5 and 8 mm anterior to the dorsal cortex of the olecranon process at angles of 20° and 30°. K-wire articular penetration was evaluated both visually and radiographically.

Results: The mean central, radial and ulnar heights of the semilunar notch were 17.3 mm (14.7-20.0), 16.2 mm (12.0-21.0) and 15.8 mm (13.30-20.5), respectively. We observed no articular penetration at the 0-mm level at 20° and 30° (0 mm 20° and 0 mm 30°, respectively) or at 5 mm 20°. At 8 mm 30° wire introduction, more than 64% articular penetration was observed on either facet. The sequence from least to most likely to cause articular penetration was: 0 mm = 5 mm 20° > 5 mm 30° = 8 mm 20° > 8 mm 30°. The radial height of the semilunar notch was negatively correlated to the risk of articular penetration, when the wire was introduced at 8 mm 30°, 8 mm 20° and 5 mm 30° (all p<0.047). There were poor correlations between radiological and direct observational assessments, particularly for 8 mm 20° and 5 mm 30°. The frequency of intra-articular positioning for those observed to be radiologically extra-articular was 4/28 (14.3%) for 8 mm 30°, 4/7 (57.1%) for 8 mm 20° and 5/6 (83.3%) for 5 mm 30°.

Conclusion: When applying the modified tension band wiring technique to prevent articular penetration, K-wires should be inserted in the first 5 mm from dorsal cortex of the olecranon process at a maximum angle of 20°. Moreover, if the wires are required to be inserted more anteriorly because of the anatomical configuration of the fracture, they should be inserted at a shallow angle in the sagittal plane in relation to the proximal cortex of the ulna.

Download full-text PDF

Source
http://dx.doi.org/10.3944/AOTT.2015.14.0155DOI Listing

Publication Analysis

Top Keywords

articular penetration
28
20° 30°
28
30° 20°
16
modified tension
12
tension band
12
band wiring
12
semilunar notch
12
articular
9
wiring technique
8
k-wires inserted
8

Similar Publications

The synovium is a loose connective tissue that separates the intra-articular (IA) joint compartments of all diarthrodial joints from the systemic circulation. It can be divided into two layers: the intima, a thin and cell-dense layer atop a more heterogeneous subintima, composed of collagen and various cell types. The subintima contains penetrating capillaries and lymphatic vessels that rapidly clear injected drugs from the joint space which may vary not only with drug size and charge but also with the microstructure and composition of the intima and subintima of the synovium.

View Article and Find Full Text PDF

This work aims to address key issues in the ballistic performance of ceramic-based composite armor, particularly at the joints of spliced ​​bulletproof panels. The edge structure of C/C-SiC ceramic plates and ultra-high molecular weight polyethylene is redesigned to superimpose the joint areas. These structurally optimized composite pads are examined by numerical simulation of impact dynamics to understand their anti-penetration performance whose accuracy is then validated by live fire tests.

View Article and Find Full Text PDF

To solve the problems of insufficient stiffness and poor integrity of traditional F-type socket joints, steel screw connections are set along the longitudinal direction between rectangular pipe jacking joints. However, the mechanical properties of F-type socket joints with steel screw connections have not been fully investigated, and the influence of the coefficient of subgrade reaction has not been considered. In this work, through model tests and numerical simulations of F-type socket joints with steel screws under different coefficients of subgrade reaction, the influence of steel screws on the deformation and damage characteristics of F-type socket joints is discussed, and the bending mechanical response of F-type socket joints under different coefficients of subgrade reaction is analyzed.

View Article and Find Full Text PDF

Wood-Derived Hydrogels for Osteochondral Defect Repair.

ACS Nano

December 2024

Department of Biomaterials, Faculty of Dental Science, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.

Repairing cartilage tissue is a serious global challenge. Herein, we focus on wood skeletal structures that are highly porous for cell penetration yet have load-bearing strength, and aim to synthesize wood-derived hydrogels with the ability to regenerate cartilage tissues. The hydrogels were synthesized by wood delignification and the subsequent intercalation of citric acid (CA), which is involved in tricarboxylic acid cycles and essential for energy production, and -acetylglucosamine (NAG), which is a cartilage glycosaminoglycan, among cellulose microfibrils.

View Article and Find Full Text PDF

This study aimed to explore the construction of experimental animal models replicating cartilage defects across diverse load-bearing sites, compare self-repair conditions, and examine the role of mechanical stimulation in cartilage self-repair. Experimental animal models were established in rabbits to simulate full-thickness cartilage defects without penetrating the subchondral bone, at various load-bearing sites, including the posterior femoral condyle, anterior femoral condyle and femoral trochlear of knee joint, and the humerus of the shoulder joint. The successful exposure and construction of cartilage defects at the anterior femoral condyle, femoral trochlear, and posterior femoral condyle through the medial extension of surgical incision.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!