Purpose: To evaluate radiographic and clinical outcomes of immediate occlusally loaded one-piece zirconia implants after 5 years of follow-up.
Materials And Methods: This longitudinal clinical investigation included patients older than 18 years, in need of implant-supported single-unit dental rehabilitations. One-piece zirconia in healed and postextraction sites and immediately restored with provisional crowns in light occlusal contact. Definitive zirconia-ceramic restorations were delivered 3 to 4 months after surgery. Primary estimated outcomes were implant survival and success. Periapical radiographs were taken at implant insertion (T0), after 1 year (T1), and after 5 years (T2) to assess marginal bone loss (MBL). Probing depth (PD), modified Bleeding Index (mBI), modified Plaque Index (mPI), and gingival recession (REC) were also measured repeatedly for implants and reference teeth. Changes in parameters over time were assessed using the Wilcoxon signed rank test. In addition, multilevel mixed effects linear and logistic regression models were fitted to take into account within-subject correlations and baseline values.
Results: Thirty-two implants were inserted in postextraction and healed sites (n = 16 of each) in 17 patients. One immediate implant was lost after 3 months, and one patient with one implant dropped out after T1. Therefore, the cumulative survival rates were 96.9% at T1 and 96.8% at T2 (4.3 to 6 years). No significant differences were observed in mean MBL between immediate and delayed implants at either T1 or T2. Moreover, different baseline parameters (sex, arch, implant location, smoking habits, grafting) did not show any influence on MBL at either time. In general, for all clinical parameters (PD, mBI, mPI, REC), implants seemed to perform similar to if not better than natural teeth.
Conclusion: Radiographic and clinical evaluations after 5 years showed satisfactory amounts of MBL and acceptable soft tissue health.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.11607/jomi.3831 | DOI Listing |
J Prosthodont Res
January 2025
School and Hospital of Stomatology, Fujian Medical University, Fuzhou, China.
Purpose: This study aimed to evaluate the effect of functional loading on microgaps and microleakage at implant-abutment interfaces (IAIs) in the aesthetic zone when using different abutments and to provide a clinical reference for abutment selection.
Methods: This study included 30 patients with 36 implants divided into three groups: zirconia (Zr)-one-piece custom abutment, titanium (Ti)-custom abutment, and Ti-original abutment. Scanning electron microscopy was used to examine alterations in the microgaps at the IAIs under functional loading.
Clin Oral Implants Res
December 2024
Department of Oral and Maxillofacial Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
Objective: To assess the clinical, radiographic and patient-reported outcome measures, and the success of screw-retained one-piece monolithic zirconia implant-supported restorations in the posterior region during a 1-year follow-up.
Methods: In a prospective case series, 50 single molar sites in the posterior region of 41 patients with a minimum age of 18 years and sufficient bone volume for placing an implant (≥ 8 mm) and space for an anatomical restoration were included. Following prosthetic-driven digital three-dimensional treatment planning, a tissue-level implant with an internal connection was inserted during a one-stage surgical procedure.
Materials (Basel)
September 2024
Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara 06100, Turkey.
While zirconia implants exhibit osseointegration comparable to that of titanium, concerns arise regarding low-temperature degradation and its potential impact on fracture strength. This study investigated the phase transformation and fracture characteristics of zirconia dental implants after aging through chewing simulation and subsequent static loading. The experimental setup involved 48 one-piece monobloc zirconia implants with diameters of 3.
View Article and Find Full Text PDFJ Prosthet Dent
October 2024
Professor, Clinic of Masticatory Disorders and Dental Biomaterials, Center for Dental Medicine, University of Zürich, Zürich, Switzerland. Electronic address:
Statement Of Problem: The outcome of posterior nonvital teeth depends not only on endodontic factors but also on the effectiveness of the restoration. The growing trend in minimally invasive dentistry has led to increasing interest in 1-piece endodontic crowns as an alternative restoration. Nevertheless, their indications and longevity lack extensive exploration, thereby limiting their widespread acceptance in dental practice.
View Article and Find Full Text PDFDent J (Basel)
August 2024
Department of Dental Prosthetics, Faculty of Dentistry, Medical University of Gdansk, 80-210 Gdansk, Poland.
Implant abutments are essential components of implant prosthetic restorations. The golden standard for abutment material is titanium; however, due to its properties, the esthetic result can be compromised. The most popular esthetic material alternatives are one- and two-piece zirconia.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!