A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A multicenter randomized comparative trial of implants with different abutment interfaces to replace anterior maxillary single teeth. | LitMetric

Purpose: The implant-abutment interface may affect peri-implant mucosal architecture, and influence health and esthetics. The goal of this 1-year follow-up report of a 5-year clinical investigation was to examine the peri-implant mucosal tissue responses to different implant-abutment interface designs.

Materials And Methods: Subjects requiring an anterior maxillary implant were recruited. Tooth extractions, with or without preservation or ridge augmentation procedures, were performed as required. After 5 months of healing, one of three different implant-abutment combinations (conical interface [CI] n = 48); flat-to-flat interface [FI] n = 49); or platform switch interface [PS] n = 44) was placed and provisionalized. Twelve weeks later, permanent crowns were placed and data gathered throughout the first year. Peri-implant mucosal architecture and bone levels were evaluated clinically, photographically, and radiographically.

Results: At 1 year, seven FI and six PS implants failed and two FI and two PS implant participants were lost to follow-up, resulting in survival rates of 100% (CI), 85.7% (FI), and 86.4% (PS) (90.8% overall). Marginal bone level changes were -0.22 mm (CI, P < .05), -1.2 mm (FI, P < .05), and -1.32 mm (PS, P < .05) after 1 year. Marginal bone level stability (≤ 0.5-mm bone loss or gain) was recorded for 87% (CI), 8% (FI), and 27% (PS) of implants. Measurement of midbuccal mucosal zenith and papilla positions revealed no change in the mucosal positions and 0.2 to 0.3 mm of gain in papilla dimensions in all groups.

Conclusion: Significant differences in marginal bone loss were observed among the three implant-abutment interfaces. At 1 year follow-up, changes in the buccal mucosal zenith position or papilla dimensions were not discernable. A continued longitudinal evaluation of peri-implant bone and mucosal changes around these different interfaces is ongoing.

Download full-text PDF

Source
http://dx.doi.org/10.11607/jomi.3772DOI Listing

Publication Analysis

Top Keywords

peri-implant mucosal
12
marginal bone
12
anterior maxillary
8
implant-abutment interface
8
mucosal architecture
8
three implant-abutment
8
bone level
8
bone loss
8
mucosal zenith
8
papilla dimensions
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!