Cerebral microaneurysms, which are 2 mm or small in size, are a rare cause of subarachnoid hemorrhage (SAH). The authors present 2 cases with ruptured microaneurysms, in which 3-dimensional (3D) fast spin-echo T1 imaging with variable flip angles (CUBE T1) using gadolinium-diethylenetriaminepentaacetic acid (Gd) enhancement was useful in diagnosing the microaneurysms as the source of bleeding. Case 1 was a 61-year-old woman who had an SAH localized to the left Sylvian fissure. A small bulge (1.4 mm) at the bifurcation of left middle cerebral artery (MCA), which was detected by 3D angiography, was well enhanced by CUBE T1 with Gd enhancement. The patient was successfully treated by trapping of the lower division of the left M2 segment with superficial temporal artery-M3 bypass. The intraoperative findings indicated that the microaneurysm at the bifurcation of the left MCA was the ruptured site. Case 2 was a 41-year-old man who had a diffuse SAH. A small bulge (1.5 mm) at the inferolateral wall of the left internal carotid artery (ICA), which was detected by 3D angiography, was well enhanced by CUBE T1 with Gd enhancement. The patient was treated by trapping of the left ICA with external carotid artery-saphenous vein graft-M2 bypass without complications. The intraoperative findings indicated that the microaneurysm at the inferolateral wall of the left ICA was the ruptured site. CUBE T1 with Gd enhancement was useful as an adjunctive tool for the diagnosis of ruptured cerebral microaneurysms. This sequence might enable neurosurgeons to perform curative surgery with certainty for ruptured microaneurysms.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jstrokecerebrovasdis.2015.04.031DOI Listing

Publication Analysis

Top Keywords

cube enhancement
12
ruptured cerebral
8
3-dimensional fast
8
fast spin-echo
8
spin-echo imaging
8
imaging variable
8
variable flip
8
flip angles
8
cerebral microaneurysms
8
ruptured microaneurysms
8

Similar Publications

With climate extremes' rising frequency and intensity, robust analytical tools are crucial to predict their impacts on terrestrial ecosystems. Machine learning techniques show promise but require well-structured, high-quality, and curated analysis-ready datasets. Earth observation datasets comprehensively monitor ecosystem dynamics and responses to climatic extremes, yet the data complexity can challenge the effectiveness of machine learning models.

View Article and Find Full Text PDF

PbZrTiO cubes with tunable sizes and cuboids have been hydrothermally synthesized. PbZrTiO cubes with three different Zr : Ti atomic percentages were also prepared. Analysis of synchrotron X-ray diffraction (XRD) patterns reveals the presence of two lattice components for these samples.

View Article and Find Full Text PDF

This study emphasizes the importance of optimizing pin-finned heat sinks as a means of addressing thermal engineering issues. It aims to investigate the use of perforations and unique fin designs in relation to staggered pin arrays in order to fill a gap in existing research. Three-dimensional incompressible flow simulation is performed with the Fluent software.

View Article and Find Full Text PDF

Crystal-facet heterojunction engineering of mesoporous nanoreactors with highly redox-active represents an efficacious strategy for the transformation of CO into valuable C products (e.g., CH).

View Article and Find Full Text PDF

Purpose: Compressed Sensing (CS) is an emerging technique to accelerate MRI acquisitions. The aim of this study was to assess the reliability and accuracy of cartilage thickness measurements in the knee using a CS-enabled isotropic 3D Fast Spin-Echo (FSE) sequence on a 3-T MRI scanner.

Methods: Twenty-eight tibial condyle sections were collected from 14 adult patients who underwent total knee arthroplasty.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!