Aortic blood pressure measured via EIT: investigation of different measurement settings.

Physiol Meas

Systems Division, Swiss Center for Electronics and Microtechnology (CSEM), Neuchâtel, Switzerland. Signal Processing Laboratory (LTS5), Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.

Published: June 2015

Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss-Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss-Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0967-3334/36/6/1147DOI Listing

Publication Analysis

Top Keywords

blood pressure
16
aortic blood
12
aortic signal
12
aortic
10
eit
10
measurement settings
8
pressure estimation
8
eit image
8
image sequences
8
belt placement
8

Similar Publications

Midodrine for Intradialytic Hypotension.

Nephrol Nurs J

January 2025

Professor of Pharmacy Practice, Clinical Pharmacotherapy Specialist, Nephrology & Dialysis, Arnold &Marie Schwartz College of Pharmacy and Health Sciences, Long Island University, Brooklyn, NY.

Intradialytic hypotension (IDH) is a common occurrence in hemodialysis. IDH occurs when there is a drop in blood pressure along with hypotensive symptoms. There are various causes of IDH, and it is important to consider proper management of this condition.

View Article and Find Full Text PDF

The Kidney Health Score: A Practical Guide to Early Detection of Kidney Disease Risk for Optimal Kidney Health.

Nephrol Nurs J

January 2025

Professor of Medicine, Department of Internal Medicine, Division of Nephrology, School of Medicine, Virginia Commonwealth University.

Chronic kidney disease (CKD) affects 10% of the global population, with increasing prevalence driven by diabetes, hypertension, and aging populations. CKD often progresses asymptomatically, frequently undetected until advanced stages, and may require costly treatments, such as dialysis or transplantation. CKD imposes a substantial financial burden on health care systems, with management costs rising sharply as the disease progresses, underscoring the need for early, cost-effective interventions.

View Article and Find Full Text PDF

Introduction: Removing uremic toxins from the body is one of the most critical points in the maintenance hemodialysis (MHD) population. This study aimed to evaluate the effects of medium cutoff (MCO) membranes on pulse wave velocity (PWV) and augmentation index (AIx), early markers of arterial stiffness, in MHD patients over both short- and long-term periods.

Methods: Twenty MHD patients were included in this study.

View Article and Find Full Text PDF

Estrogen significantly impacts women's health, and postmenopausal hypertension is a common issue characterized by blood pressure fluctuations. Current control strategies for this condition are limited in efficacy, necessitating further research into the underlying mechanisms. Although metabolomics has been applied to study various diseases, its use in understanding postmenopausal hypertension is scarce.

View Article and Find Full Text PDF

Association of Mobile Stroke Unit Care and Spending, Utilization, and Death in New York City.

J Am Heart Assoc

January 2025

Department of Population Health Sciences Weill Cornell Medicine New York NY.

Background: Transport by mobile stroke units (MSUs), which provide access to computed tomography scanning and intravenous blood pressure medications and thrombolytics, reduces time to treatment and may improve short-term functional outcomes for patients with acute stroke. The longer-term clinical and financial impacts remain incompletely understood. The aim of the study was to determine whether MSU care is associated with better health, utilization, and spending outcomes for patients with suspected acute stroke.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!