We compared data obtained with the Kodak Ektachem and Hitachi 717 Analysers and HPLC from 83 neonates under phototherapy. Total bilirubin values determined with the Kodak and Hitachi are in good agreement, but we observed a large discrepancy in the results for conjugated (Kodak) and direct (Hitachi) bilirubin. HPLC revealed that all the samples contained configurational isomers, while only 7.

View Article and Find Full Text PDF

The effects of light on serum bilirubin subfractions in vitro were investigated by HPLC and four routine methods for bilirubin analysis. By HPLC, the rate of photodegradation of unconjugated bilirubin (Bu) was nearly twice that of monoconjugated bilirubin (mBc) and threefold that of diconjugated bilirubin (dBc); delta bilirubin (Bd) was most stable against photoirradiation. In the diazo method, the rate of photodegradation of direct bilirubin was almost the same as that of the sum of mBc, dBc, and Bd determined by the HPLC method.

View Article and Find Full Text PDF

Guidelines for managing hyperbilirubinemia in newborns were developed by using diazo methods that measure total and direct-reacting bilirubins and calculate an indirect fraction. The automated Kodak Ektachem system allows for measuring serum bilirubin by either of two dry-slide methods: TBIL, involving a modified diazo method, and NBIL, involving a dual-wavelength colorimetric method that fractionates and directly measures the unconjugated (Bu) and conjugated (Bc) bilirubins (Bu+Bc = neonatal bilirubin). The manufacturer recommends that NBIL be used in newborns less than 15 days old, which is impractical in a large, busy hospital laboratory.

View Article and Find Full Text PDF

Serum delta bilirubin estimation by an automated method.

Eur J Clin Chem Clin Biochem

January 1992

Department of Pediatrics, Cedars-Sinai Medical Center, Los Angeles, CA.

This study compares delta bilirubin values in 40 serum samples from patients with various diagnoses, as estimated by the automated Kodak Ektachem system and measured by a manual method. Regression analysis of the results yielded a slope = 0.832, intercept = 9.

View Article and Find Full Text PDF

This study compares total and direct-reacting bilirubin values in 40 serum samples from patients with various diagnoses, as measured by automated methods (Beckman Synchron CX-5, Beckman Astra 8, Kodak Ektachem 700) and HPLC and by a manual method for delta bilirubin. For total bilirubin, within-run CVs were less than 6%. The Ektachem 700 method underestimated bilirubin with serum samples from patients with Crigler-Najjar syndrome and from newborns in whom unconjugated bilirubin concentrations were increased but conjugated bilirubins were not present or were present only in small amounts.

View Article and Find Full Text PDF