Background: The beneficial effects of the transcatheter aortic valve implantation (TAVI) on echocardiographic parameters including left atrial (LA) and left ventricular (LV) functions were described by previous studies. The aim of this study was to analyze the effects of TAVI on left atrial appendage (LAA) function assessed by transthoracic and transesophageal echocar-diography.

Methods: Fifty-five patients with severe symptomatic aortic stenosis were included in this prospective study. LAA early and late emptying velocities, LAA filling velocity, peak early diastolic (EM), late diastolic (AM), and systolic (SM) velocities were measured with pulsed wave Doppler and tissue Doppler imaging, and E/Em ratio was calculated before and 7.1 ± 2.8 days after TAVI. A subgroup analysis was performed in accordance with the left ventricular ejection fraction (LVEF) of the patients and the severity of their LV diastolic dysfunction.

Results: Although the post-procedure peaks and mean gradients of the patients decreased sig-nificantly, the LVEF increased significantly in those who had low LVEF before the procedure. The post-procedure E/Em ratio decreased significantly (p < 0.001). The post-procedural LAA mean filling velocity and EM velocity were significantly higher than the pre-procedural filling velocity (p < 0.001, p = 0.002, respectively). In the subgroup analysis, the post-procedural LAA filling velocity, early and late LAA emptying velocities, in addition to the mean velocity of the EM, AM, and SM were significantly higher than before the procedure in patients with LVEF of < 50% and E/Em ratios of > 15.

Conclusions: LAA function improved soon after the TAVI procedure, especially in patients with low LVEF and marked LV diastolic dysfunction.

Download full-text PDF

Source
http://dx.doi.org/10.5603/CJ.a2015.0024DOI Listing

Publication Analysis

Top Keywords

filling velocity
16
left atrial
12
laa filling
12
effects transcatheter
8
transcatheter aortic
8
aortic valve
8
valve implantation
8
atrial appendage
8
left ventricular
8
laa function
8

Similar Publications

This study investigates fixed and moving mesh methodologies for modeling liquid metal-free surface deformation during the induction melting process. The numerical method employs robust coupling of magnetic fields with the hydrodynamics of the turbulent stirring of liquid metal. Free surface tracking is implemented using the fixed mesh level set (LS) and the moving mesh arbitrary Lagrangian-Eulerian (ALE) formulation.

View Article and Find Full Text PDF

Introduction: The venous outflow profile (VOP) is a crucial yet often overlooked aspect affecting stroke outcomes. It plays a major role in the physiopathology of acute cerebral ischemia, as it accounts for both the upstream arterial collaterals and cerebral microperfusion. This enables it to circumvent the limitations of various arterial collateral evaluation systems, which often fail to consider impaired autoregulation and its impact on cerebral blood flow at the microcirculatory levels.

View Article and Find Full Text PDF

CFD Analysis of Particle Dynamics in Accelerated Toroidal Systems for Enhanced PIVG Performance.

Micromachines (Basel)

November 2024

Department of Mechanical and Manufacturing Engineering, Schulich School of Engineering, University of Calgary, 2500 University Dr. NW, Calgary, AB T2N 1N4, Canada.

This study investigates the movements of particles in an accelerated toroidal flow channel filled with water, with specific applications for a particle imaging velocimetry gyroscope (PIVG). We used computational fluid dynamics (CFD) to simulate particle behavior under different angular accelerations. These angular accelerations were 4 rad/s, 6 rad/s, and 8 rad/s for particles densities of 1100 kg/m, 1050 kg/m, and 980 kg/m.

View Article and Find Full Text PDF

Numerical modeling of conventional spin-stop agitation of liquid drug products for automated visual inspection.

Int J Pharm

January 2025

Amgen Inc., Process Development, Manufacturing Technology Advancement (MTA) Group, Thousand Oaks, CA 91320, USA. Electronic address:

Article Synopsis
  • The automated visual inspection (AVI) of liquid-filled vials and syringes in pharmaceutical production uses a spin-stop motion to detach particles for better detection.
  • A validated numerical model for a specific glass vial was created to study how different agitation motions and liquid properties affect particle mobilization.
  • Findings indicate that higher angular acceleration during agitation improves the wall shear stress distribution, enhancing particle detection, and the developed model can be adapted for various container types and liquids to optimize AVI processes.
View Article and Find Full Text PDF

Uneven of filling aggregate gradation may cause transportation problems such as pipe blockage due to segregation and stratification of filling slurry. To study the influence of aggregate gradation on the conveying performance of filler slurry, aggregate gradation experiments were carried out, rheological tests on slurries with coal gangue/aeolian sand ratios (6:4, 5:5 and 4:6) showed that appropriately increasing the proportion of aeolian sand can improve particle gradation. Computational fluid dynamics (CFD) scheme was used to simulate the pipeline transportation characteristics of the slurry under the conditions of three sets each of coal gangue/aeolian sand ratios, slurry concentrations (72%,74% and 76%), and inlet velocities (1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!