Doppler-free saturated-absorption Lamb dips were measured on weak rovibrational lines of (12)C(16)O2 between 6189 and 6215 cm(-1) at sub-Pa pressures using optical feedback frequency stabilized cavity ring-down spectroscopy. By referencing the laser source to an optical frequency comb, transition frequencies for ten lines of the 30013←00001 band P-branch and two lines of the 31113←01101 hot band R-branch were determined with an accuracy of a few parts in 10(11). Involving rotational quantum numbers up to 42, the data were used for improving the upper level spectroscopic constants. These results provide a highly accurate reference frequency grid over the spectral interval from 1599 to 1616 nm.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.4921557DOI Listing

Publication Analysis

Top Keywords

transition frequencies
8
communication saturated
4
saturated co2
4
co2 absorption
4
absorption μm
4
μm kilohertz-accuracy
4
kilohertz-accuracy transition
4
frequencies doppler-free
4
doppler-free saturated-absorption
4
saturated-absorption lamb
4

Similar Publications

This study presents the design of a high-gain 16 × 16-slot antenna array with a low sidelobe level (SLL) using a tapered ridge gap waveguide feeding network for Ka-band applications. The proposed antenna element includes four cavity-backed slot antennas. A tapered feeding network is designed and utilized for unequal feeding of the radiating elements.

View Article and Find Full Text PDF

Breast cancer is a leading cause of cancer-related deaths among women globally. It is imperative to explore novel biomarkers to predict breast cancer treatment response as well as progression. Here, we collected six breast cancer samples and paired normal tissues for high-throughput sequencing.

View Article and Find Full Text PDF

Background: There is an under-reporting of anaesthesia-related safety events. Incident-capturing systems (ICSs) are essential for patient safety monitoring, identifying risks and ongoing opportunities for improvement. After a literature review and assessment of our current ICSs, we concluded that our institution lacked a reliable anaesthesia-specific ICS system, leading to under-reporting of anaesthesia-related safety events.

View Article and Find Full Text PDF

Aims: To describe a type 1 diabetes melllitus (T1DM) transition care model by assessing clinic attendance, glycemic management, and diabetes-related hospitalizations.

Methods: This is a descriptive longitudinal single-center study of patients with T1DM aged 18 to 25 referred to our transition clinic from 2012 to 2021 (N=179).

Results: Our data analysis demonstrates an average clinic attendance rate of 79% and mean time between last pediatric and first adult visit of 6.

View Article and Find Full Text PDF

Background: Clinical decision-making is increasingly shifting towards data-driven approaches and requires large databases to develop state-of-the-art algorithms for diagnosing, detecting and predicting diseases. The intensive care unit (ICU), a data-rich setting, faces challenges with high-frequency, unstructured monitor data. Here, we showcase a successful example of a data pipeline to efficiently move patient data to the cloud environment for structured storage.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!