Background: In the context of a community-randomized trial of antiretrovirals for HIV prevention and treatment among sex workers in Zimbabwe (the SAPPH-IRe trial), we will measure the proportion of women with HIV viral load (VL) above 1000 copies/mL ("VL>1000") as our primary endpoint. We sought to characterize VL assay performance by comparing results from finger prick dried blood spots (DBS) collected in the field with plasma samples, to determine whether finger prick DBS is an acceptable sample for VL quantification in the setting.

Methods: We collected whole blood from a finger prick onto filter paper and plasma samples using venipuncture from women in two communities. VL quantification was run on samples in parallel using NucliSENS EasyQ HIV-1 v2.0. Our trial outcome is the proportion of women with VL>1000, consistent with WHO guidelines relating to regimen switching. We therefore focused on this cut-off level for assessing sensitivity and specificity. Results were log transformed and the mean difference and standard deviation calculated, and correlation between VL quantification across sample types was evaluated.

Results: A total of 149 HIV-positive women provided DBS and plasma samples; 56 (63%) reported being on antiretroviral therapy. VL ranged from undetectable-6.08 log10 using DBS and undetectable-6.40 log10 using plasma. The mean difference in VL (plasma-DBS) was 0.077 log10 (95%CI = 0.025-0.18 log10; standard deviation = 0.63 log10,). 78 (52%) DBS and 87 (58%) plasma samples had a VL>1000. Based on plasma 'gold-standard', DBS sensitivity for detection of VL>1000 was 87.4%, and specificity was 96.8%.

Conclusion: There was generally good agreement between DBS and plasma VL for detection of VL>1000. Overall, finger prick DBS appeared to be an acceptable sample for classifying VL as above or below 1000 copies/mL using the NucliSENS assay.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4441418PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0126878PLOS

Publication Analysis

Top Keywords

finger prick
20
plasma samples
16
prick dried
8
dried blood
8
blood spots
8
hiv viral
8
viral load
8
proportion women
8
1000 copies/ml
8
dbs
8

Similar Publications

Background: The Highlands of Papua New Guinea are non-endemic for malaria compared to the rest of the country. This study aimed to explore the local transmission of malaria in the Highlands through a cross-sectional school survey coupled with reactive case detection.

Methods: Between July and November 2019, 5575 schoolchildren and 1048 household members were screened for malaria using Rapid Diagnostic Tests, subsequently validated by light microscopy.

View Article and Find Full Text PDF

Background: Studies on the accuracy of point-of-care (POC) testing using capillary samples are scarce. Therefore, this study aimed to assess the analytical accuracy of POC testing for white blood cell (WBC) and C-reactive protein (CRP) using capillary samples compared with conventional central laboratory testing using venous samples in a pediatric ambulatory care setting.

Methods: This was a retrospective study including patients younger than 18 years who underwent concurrent WBC and CRP evaluations via capillary and subsequent venous sampling within a 2-h window.

View Article and Find Full Text PDF

This study aimed to develop tuber bread from purple sweet potato and bambara beans with high satiety and low glycemic index (GI). Different ratios of purple sweet potato to bambara bean were used: 100:0 (F0), 80:20 (F1), 60:40 (F2), and 40:60 (F3). The satiety index (SI) was determined by assessing the consumption of a 240 kcal isocaloric food and collecting data through a visual analog scale.

View Article and Find Full Text PDF

Accurate and continuous blood glucose monitoring is essential for effective diabetes management, yet traditional finger pricking methods are often inconvenient and painful. To address this issue, photoplethysmography (PPG) presents a promising non-invasive alternative for estimating blood glucose levels. In this study, we propose an innovative 1-second signal segmentation method and evaluate the performance of three advanced deep learning models using a novel dataset to estimate blood glucose levels from PPG signals.

View Article and Find Full Text PDF

Background: As older age and having certain comorbidities can influence humoral responses to vaccination, we studied antibody responses after the COVID-19 booster campaigns in nursing home (NH) residents.

Methods: In a two year longitudinal study with Dutch NH residents (n = 107), aged 50 years and over, we monitored antibody responses in serum prior to and after vaccination with a third, fourth BNT162b2 (wild-type; WT), and a BNT162b2 bivalent (WT/OMI BA.1) fifth vaccine.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!