Background: Repeat cardiac surgeries are well known to have higher rates of complications, one of the important reasons being injuries associated with re-do sternotomy. Routine imaging with CT can help to minimise this risk by pre-operatively assessing the anatomical relation between the sternum and the underlying cardiovascular structures, but is limited by its inability to determine the presence and severity of functional tethering and adhesions between these structures. However, with the evolution of wide area detector MD CT scanners, it is possible to assess the presence of tethering using the dynamic four-dimensional CT (4D CT) imaging technique.

Methods: Nineteen patients undergoing re-do cardiac surgery were pre-operatively imaged using dynamic 4D CT during regulated respiration. The datasets were assessed in cine mode for presence of differential motion between sternum and underlying cardiovascular structures which indicates lack of significant tethering.

Results: Overall, there was excellent correlation between preoperative imaging and intraoperative findings. The technique enabled our surgeons to meticulously plan the procedures and to avoid re-entry related injuries.

Conclusions: Our initial experience shows that dynamic 4D CT is useful in risk stratification prior to re-do sternotomy by determining the presence or absence of tethering between sternum and underlying structures based on assessment of differential motion. Furthermore we determined the technique to be superior to non-dynamic assessment of retrocardiac tethering.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hlc.2015.02.027DOI Listing

Publication Analysis

Top Keywords

re-do sternotomy
12
sternum underlying
12
dynamic four-dimensional
8
underlying cardiovascular
8
cardiovascular structures
8
differential motion
8
dynamic
4
four-dimensional computed
4
computed tomography
4
imaging
4

Similar Publications

Background: Over the last decade, the number of simultaneous heart-kidney transplants (SHKTs) has increased dramatically. There are few reports of renal allograft outcomes in these high acuity patients. The goal of the present study was to identify variables that were related to early adverse outcomes (EAOs), including delayed graft function (DGF), primary non-function (PNF), and renal allograft futility (RAF) after SHKTs.

View Article and Find Full Text PDF

A 42-year-old female patient with a surgical history of iliac venous angioplasty with stenting developed dyspnea on exertion 9 months later. Chest computed tomography angiography revealed a fractured vascular stent in the right cardiac chamber. Doppler echocardiography confirmed that the stent was anchored by the tricuspid valve, causing mild obstruction of the right ventricular filling.

View Article and Find Full Text PDF

Objective: Re-do root replacement poses a significant technical challenge, increasing the potential risk of morbidity and mortality. This multi-institution study compared the outcomes of aortic root replacement stratified by chest surgery and aortic root history.

Methods: A retrospective review by the Western Aortic Collaborative was performed of 3 different aortic centers for patients who underwent nonemergency root replacement from 2017 to 2023 with exclusion of patients who underwent more than hemiarch replacement or presented with acute or hyperacute aortic dissection.

View Article and Find Full Text PDF

This case report details the management of a 79-year-old man who developed massive postoperative pneumothorax following redo coronary artery bypass grafting due to severe lung adhesions. We successfully treated the patient using veno-venous extracorporeal membrane oxygenation without femoral cannulation, allowing for early rehabilitation initiation. Veno-venous extracorporeal membrane oxygenation is a reasonable option for cases of severe respiratory failure due to pneumothorax with lung destruction caused by re-sternotomy during re-do cardiac surgery.

View Article and Find Full Text PDF

Purpose: Ascending aortic pseudoaneurysms are a common phenomenon requiring surgical intervention but can pose high surgical risks in medically complex patients. We report a novel approach to percutaneous closure of ascending aortic pseudoaneurysms using an Amplatzer PFO closure device.

Case Report: We present the case of a 65-year-old male with haemoptysis on a background of multiple cardiac surgeries and chronic kidney disease.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?