The environmental impact of the Glostavent® anesthetic machine.

Anesth Analg

From the *Safe Anaesthesia Worldwide, Marden, Kent, United Kingdom; and †Diamedica (UK) Ltd., Barnstaple, Devon, United Kingdom.

Published: June 2015

Because anesthetic machines have become more complex and more expensive, they have become less suitable for use in the many isolated hospitals in the poorest countries in the world. In these situations, they are frequently unable to function at all because of interruptions in the supply of oxygen or electricity and the absence of skilled technicians for maintenance and servicing. Despite these disadvantages, these machines are still delivered in large numbers, thereby expending precious resources without any benefit to patients. The Glostavent was introduced primarily to enable an anesthetic service to be delivered in these difficult circumstances. It is smaller and less complex than standard anesthetic machines and much less expensive to produce. It combines a drawover anesthetic system with an oxygen concentrator and a gas-driven ventilator. It greatly reduces the need for the purchase and transport of cylinders of compressed gases, reduces the impact on the environment, and enables considerable savings. Cylinder oxygen is expensive to produce and difficult to transport over long distances on poor roads. Consequently, the supply may run out. However, when using the Glostavent, oxygen is normally produced at a fraction of the cost of cylinders by the oxygen concentrator, which is an integral part of the Glostavent. This enables great savings in the purchase and transport cost of oxygen cylinders. If the electricity fails and the oxygen concentrator ceases to function, oxygen from a reserve cylinder automatically provides the pressure to drive the ventilator and oxygen for the breathing circuit. Consequently, economy is achieved because the ventilator has been designed to minimize the amount of driving gas required to one-seventh of the patient's tidal volume. Additional economies are achieved by completely eliminating spillage of oxygen from the breathing system and by recycling the driving gas into the breathing system to increase the Fraction of Inspired Oxygen (FIO2) at no extra cost. Savings also are accrued when using the drawover breathing system as the need for nitrous oxide, compressed air, and soda lime are eliminated. The Glostavent enables the administration of safe anesthesia to be continued when standard machines are unable to function and can do so with minimal harm to the environment.

Download full-text PDF

Source
http://dx.doi.org/10.1213/ANE.0000000000000737DOI Listing

Publication Analysis

Top Keywords

oxygen concentrator
12
breathing system
12
oxygen
11
anesthetic machines
8
unable function
8
expensive produce
8
purchase transport
8
glostavent enables
8
oxygen breathing
8
driving gas
8

Similar Publications

The electricity cost burden of durable medical equipment in the United States.

Sci Rep

December 2024

Paul H. O'Neill School of Public and Environmental Affairs, Indiana University, Bloomington, USA.

Those who rely on durable medical equipment (DME) for their health are more likely to be energy insecure and face higher energy burdens than those who do not. In this article, we evaluate the costs of electricity to run DMEs. We find that the average cost across the most common types of high-frequency DMEs-including oxygen concentrators, continuous positive airway pressure machines, and peritoneal kidney dialysis machines-is between $120 and $333 per year, depending on device size and usage frequency.

View Article and Find Full Text PDF

Background: Patients can experience persistent cognitive complaints and deficits in long-COVID. Inflammation and capillary damage may contribute to symptoms by interfering with tissue oxygenation.

Methods: This was an exploratory pilot crossover study designed to describe the effects of supplemental oxygen (portable oxygen concentrator, POC) on cognitive performance and peripheral and cerebral oxygen saturation at rest and exercise.

View Article and Find Full Text PDF

Extended oxygen supplementation after thoracotomy in rats may improve welfare.

Lab Anim

November 2024

Paragon Veterinary Referrals, Wakefield, UK.

A retrospective comparison of welfare indicators in male rats undergoing thoracotomy for intrapleural dosing is presented. The initial cohort ( = 7) breathed room air after recovery from anaesthesia, while later cohorts ( = 12) had oxygen supplementation for up to 48 h post-surgery. Rats breathing room air sustained a statistically significant average body-weight loss of -1.

View Article and Find Full Text PDF

Importance: The Medicare Competitive Bidding Program (CBP), a policy that reduced durable medical equipment prices, was implemented starting in 2011. Legislation introduced in 2024 aims to remove supplemental oxygen from the CBP because of concerns that recent decreases in oxygen prescribing are due to lower prices set by the CBP, which may have decreased supply and, in turn, limited oxygen access for patients with chronic lung diseases. However, low-value prescribing of oxygen is also prevalent in practice, and decreased oxygen prescription rates may not have necessarily caused harm.

View Article and Find Full Text PDF

Background: Excessive daytime sleepiness (EDS) is a complex sleep problem that affects approximately 33% of the United States population. Although EDS usually occurs in conjunction with insufficient sleep, and other sleep and circadian disorders, recent studies have shown unique genetic markers and metabolic pathways underlying EDS. Here, we aimed to further elucidate the biological profile of EDS using large scale single- and pathway-level metabolomics analyses.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!