Field validation of a Leishmania (Leishmania) mexicana exo-antigens ELISA for diagnosing tegumentary leishmaniasis in regions of Leishmania (Viannia) predominance.

Braz J Infect Dis

Pós-Graduação em Ciências Médicas, Universidade de Brasília (UnB), Brasília, DF, Brazil; Dermatology, Brasília, Universidade de Brasília (UnB), Brasília, DF, Brazil; Faculdade de Medicina, Universidade de Brasília (UnB), Brasília, DF, Brazil.

Published: July 2016

Background: Several tests are performed to obtain better accuracy when diagnosing American tegumentary leishmaniasis (ATL). It is believed that antigens released via secretion, excretion and metabolism are more specific than are antigens released by the lysis of Leishmania parasites. Such antigens are known as exo-antigens (exo-Ag) and are formed from products released by cultured parasites in a way that is similar to that in which they cause infections in hosts.

Objective: We attempted to validate a Leishmania mexicana ELISA exo-Ag for ATL diagnosis in Midwestern Brazil.

Methods: A total of 281 patients were included in the study. We analysed pre-treatment blood from 98 ATL patients; out of those, 85.7% and 14.3% had cutaneous and mucosal forms, respectively.

Results: The exo-Ag accuracy was 83.99% (95% CI=79.24-87.81) with a sensitivity value of 90.82% (95% CI=83.46-95.09) and an overall specificity value of 80.33% (95% CI=73.97-85.44). The positive predictive value and negative predictive value were 71.20% (95% CI=62.72-78.41) and 94.23% (95% CI=89.40-96.94), respectively. Among healthy controls, exo-Ag had a specificity of 91.25% (95% CI=83.02-95.70); additionally, the test had specificity rates of 66.67% (95% CI=46.71-82.03) in Chagas disease patients, 60.61% (95% CI=43.68-75.32) in patients with rheumatic diseases, 76.92% (95% CI=49.74-91.82) in pemphigus foliaceus patients, 87.50% (95% CI=52.91-97.76) in leprosy patients, 87.50% (95% CI=63.98-96.50) in VRDL-positive patients, and 77.78 (95% CI=45.26-93.68) in deep mycosis patients.

Conclusion: Based on the indicators of validity, we conclude that the results obtained in this study enable the recommendation of the exo-Ag ELISA for ATL diagnosis once it presented a reasonable accuracy compared to classical methods. Cost evaluations are necessary to completely define the role of this technique in large scale.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9425357PMC
http://dx.doi.org/10.1016/j.bjid.2015.03.010DOI Listing

Publication Analysis

Top Keywords

95%
12
leishmania mexicana
8
tegumentary leishmaniasis
8
antigens released
8
atl diagnosis
8
patients 8750%
8
8750% 95%
8
patients
7
leishmania
5
exo-ag
5

Similar Publications

Article Synopsis
  • The study measured fibrinogen fluorescence at temperatures between 20 and 80 degrees Celsius across different pH levels.
  • It was found that raising the temperature from 20 to 40 degrees Celsius did not change the structure of fibrinogen in solutions with pH between 4.5 and 9.3.
  • However, temperatures between 40 to 50 degrees Celsius caused some structural changes in neutral solutions, and temperatures above 50-55 degrees Celsius led to significant denaturation of the fibrinogen molecule.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!