Electric field measurements in the magnetic resonance (MR) imaging environment are important to assess potentially dangerous radio-frequency (RF) heating in the vicinity of metallic structures such as coils, implants or catheters. So far, E-field measurements have been performed with dipole antennas that lag of limited spatial resolution and which are difficult to use in the magnet bore as they interfere with the RF transmit field of the MRI system. In this work an electro-optic sensor is presented that utilizes the Pockels effect to measure the E-field in a clinical MR system with high spatial resolution. This sensor consists of dielectric materials only and thus, it only minimally influences the measured E-field distribution. A 10 m long flexible optical fiber connects the small sensor head to a remote processing unit where the optical signal is transformed into an electrical output signal. Spatially resolved qualitative E-field measurements were performed in a 1.5 T clinical MR system in the vicinity of metallic samples and an active tracking catheter with a resolution of up to 1 mm. The near-field pattern of a resonant U-shaped metallic sample was clearly identified and compared with numerical simulations. A more complex field behavior was found for the tracking catheter where strong E-field enhancements were observed at the distal tip and at its proximal part outside the phantom solution. Due to its sub-mm spatial resolution the optical sensor approach provides detailed insight into the complex and difficult to access field distributions close to implants and metallic structures and has turned out to be promising tool for MRI field and safety inspections.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/0031-9155/60/11/4355 | DOI Listing |
Med Phys
January 2025
Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, Canada.
Background: A stemless plastic scintillation detector (SPSD) is composed of an organic plastic scintillator coupled to an organic photodiode. Previous research has shown that SPSDs are ideally suited to challenging dosimetry measurements such as output factors and profiles in small fields. Lacking from the current literature is a systematic effort to optimize the performance of the photodiode component of the detector.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Civil and Environmental Engineering, Khalifa University of Science and Technology, Abu Dhabi, UAE.
Bathymetric mapping of the coastal area is essential for coastal development and management. However, conventional bathymetric measurement in coastal areas is resource-expensive and under many constraints. Various research have been conducted to improve the efficiency or effectiveness of bathymetric estimations.
View Article and Find Full Text PDFEnviron Pollut
January 2025
School of Public Policy and Administration, Xi'an Jiaotong University, Xi'an 710049, China.
Air pollution carries different disease burdens across all age groups, with the elderly and children being the most affected. Therefore, it is of practical significance to study air pollution exposure characteristics of different age groups in the context of accelerating aging in China. In this study, we used the number of people and air pollutant concentration data at the township-level scale (the smallest administrative unit in China) to calculate population-weighted PM concentration exposure (PM PWE) values of different age groups in the Beijing-Tianjin-Hebei (BTH) region, quantified the pollution exposure differences among different groups, and analyzed the spatiotemporal changes in such differences and their driving factors.
View Article and Find Full Text PDFPhys Med Biol
January 2025
The Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, Hubei 430074, Wuhan, Hubei, 430074, CHINA.
Objective: In-beam positron emission tomography (PET) has important development prospects in real-time monitoring of proton therapy. However, in the beam-on operation, the high bursts of radiation events pose challenges to the performance of the PET system.
Approach: In this study, we developed a dual-head in-beam PET system for proton therapy monitoring and evaluated its performance.
Behav Res Methods
January 2025
Department Neurophysics, Philipps-Universität Marburg, Fachbereich Physik, AG Neurophysik, Karl-Von-Frisch-Straße 8a, 35043, Marburg, Lahnberge, Germany.
The analysis of eye movements is a noninvasive, reliable and fast method to detect and quantify brain (dys)function. Here, we investigated the performance of two novel eye-trackers-the Thomas Oculus Motus-research mobile (TOM-rm) and the TOM-research stationary (TOM-rs)-and compared them with the performance of a well-established video-based eye-tracker, i.e.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!