Background: The position and residual motion of the chest wall of breast cancer patients during treatment in deep inspiration breath-hold (DIBH) were investigated.
Material And Methods: The study included 58 left-sided breast cancer patients treated with DIBH three-dimensional (3D) conformal radiotherapy in 15 or 25 fractions. The DIBH levels were monitored using an external marker block placed on the chest, either shifted 5 cm to the right at the level of the xiphoid process (Group 1, 27 consecutive patients) or placed medially on the inferior part of the sternum (Group 2, 31 consecutive patients). At every third treatment fraction, continuous portal images were acquired. The time-resolved chest wall position during treatment was compared with the planned position to determine the inter-fraction setup errors and the intra-fraction motion of the chest wall.
Results: The DIBH compliance was 95% during both recruitment periods. A tendency of smaller inter-fraction setup errors and intra-fraction motion was observed for group 2 (medial marker block position). However, apart from a significantly reduced inter-field random shift (σ = 1.7 mm vs. σ = 0.9 mm, p = 0.005), no statistically significant differences between the groups were found. In a combined analysis, the group mean inter-fraction setup error was M = - 0.1 mm, with random and systematic errors of σ = 1.7 mm and Σ = 1.4 mm. The group mean inter-field shift was M = 0.0 (σ = 1.3 mm and Σ = 1.1 mm) and the group mean standard deviation of the intra-field motion was 0.5 mm. The absolute setup error had a maximum of 16.3 mm, exceeding 5 mm in 2.2% of the imaged fields.
Conclusion: Compared to free breathing treatments, the primary benefit of the DIBH technique was the separation of the heart from the target rather than more accurate targeting. Despite a small gating window, occasional large errors in the chest wall position were observed for some patients, illustrating limitations of the external marker block as surrogate in a broad patient population.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3109/0284186X.2015.1045625 | DOI Listing |
Clin Chim Acta
December 2024
Newborn Screening, Clinical Biochemistry and Clinical Pharmacy Laboratory, Meyer Children's Hospital IRCCS, 50139 Florence, Italy; Department of Experimental and Clinical Biomedical Sciences "Mario Serio", University of Florence, 50139 Florence, Italy. Electronic address:
J Radiat Res
December 2024
Section of Radiation Safety and Quality Assurance, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba 277-8577, Japan.
We assessed the effect of beam size on plan robustness for intensity-modulated proton therapy (IMPT) of head and neck cancer (HNC) and compared the plan quality including robustness with that of intensity-modulated radiation therapy (IMRT). IMPT plans were generated for six HNC patients using six beam sizes (air-sigma 3-17 mm at isocenter for a 70-230 MeV) and two optimization methods for planning target volume-based non-robust optimization (NRO) and clinical target volume (CTV)-based robust optimization (RO). Worst-case dosimetric parameters and plan robustness for CTV and organs-at-risk (OARs) were assessed under different scenarios, assuming a ± 1-5 mm setup error and a ± 3% range error.
View Article and Find Full Text PDFHopfield neural networks (HNNs) promise broad applications in areas such as combinatorial optimization, memory storage, and pattern recognition. Among various implementations, optical HNNs are particularly interesting because they can take advantage of fast optical matrix-vector multiplications. Yet their studies so far have mostly been on the theoretical side, and the effects of optical imperfections and robustness against memory errors remain to be quantified.
View Article and Find Full Text PDFDisabil Rehabil Assist Technol
December 2024
New Technologies Platform, Raymond Poincaré Hospital, APHP. Université Paris Saclay, Garches, France.
Purpose: Information and communication technologies are crucial for social and professional integration, but access to technology can be difficult for people with physical impairments. Text entry can be slow and tiring. We developed a free and open-source module called for use with AAC (augmentative/alternative communication) software in French language.
View Article and Find Full Text PDFPLoS One
December 2024
Computer, Computational, and Statistical Sciences Division, Los Alamos National Laboratory, Los Alamos, NM, United States of America.
Crowdsource platforms have been used to study a range of perceptual stimuli such as the graphical perception of scatterplots and various aspects of human color perception. Given the lack of control over a crowdsourced participant's experimental setup, there are valid concerns on the use of crowdsourcing for color studies as the perception of the stimuli is highly dependent on the stimulus presentation. Here, we propose that the error due to a crowdsourced experimental design can be effectively averaged out because the crowdsourced experiment can be accommodated by the Thurstonian model as the convolution of two normal distributions, one that is perceptual in nature and one that captures the error due to variability in stimulus presentation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!