Aim: The aim of this study was to perform a comparative assessment of the toxic action of root canal sealers currently on the market on human gingival fibroblasts after setting.

Material/methods: The inserts with an equal quantity of set root canal sealers were transferred into 24-well culture dishes containing human gingival fibroblasts cultured in Dulbecco's Modified Eagle's Medium (DMEM) supplemented with 10% fetal calf serum (FCS). The dishes with materials were incubated at 37°C, 100% humidity and in an atmosphere of 5% CO2 for 24 h. The cytotoxic effects of the root canal materials were measured by the mitochondrial succinate dehydrogenase activity in living cells using tetrazolium bromide (MTT assay).

Results: Epiphany and Sealapex exhibited high toxicity towards human gingival fibroblasts - 25.57% ± 0.88 and 27.63 % ± 2.35 respectively (less than 30% live cells in the culture). The remaining materials were characterized by lack of a cytotoxic effect (over 90% of live cells in the culture). None of the preparations exhibited moderate or low toxicity.

Conclusions: The majority of root canal sealers tested after hardening were well tolerated by human gingival fibroblasts. Only two materials were characterized by high toxicity: with methacrylate (Epiphany) and calcium hydroxide (Sealapex).

Download full-text PDF

Source
http://dx.doi.org/10.5604/17322693.1150134DOI Listing

Publication Analysis

Top Keywords

root canal
20
canal sealers
16
human gingival
16
gingival fibroblasts
16
high toxicity
8
live cells
8
cells culture
8
materials characterized
8
root
5
canal
5

Similar Publications

Aim: This study evaluated the smear layer removal provided by conventional, sonic, and ultrasonic irrigation techniques.

Methodology: Forty extracted human mandibular first premolars were selected and instrumented using the ProTaper Next System files and 2.5% sodium hypochlorite.

View Article and Find Full Text PDF

Neuraxial Anesthesia and Risk of Root Damage: A 3D Ex Vivo Study.

NeuroSci

December 2024

Laboratory of Surgical Neuroanatomy (LSNA), Human Anatomy and Embryology Unit, Faculty of Medicine and Health Sciences, Universitat de Barcelona, 08036 Barcelona, Spain.

Cauda equina nerve roots may become damaged during neuraxial anesthesia, and post-puncture headache may appear in the case of cerebrospinal fluid leakage if needle tips are deformed due to bone contact when several attempts are needed. Our aim was to verify the correlation between skin-transverse process distance (st) and skin-dural sac distance (d) for calculation of optimal angles in a free visual guide and as a reference for the maximal depth to be traversed by the needle. Randomly selected ex vivo samples ( = 10) were flexed to reproduce the position of the lumbosacral spine during spinal anesthesia.

View Article and Find Full Text PDF

Objective: This study aimed to assess and compare the internal fit of custom-made posts and cores fabricated using digital impressions (DI) and conventional vinyl polysiloxane (VPS) impressions in restorative dentistry.

Materials And Methods: A typodont tooth model, simulating the anatomy of the root canal of a central incisor, was utilized for the study. Two groups were formed, Group A and Group B, and each group provided a total of 18 impressions of two types: DIs and VPS impressions.

View Article and Find Full Text PDF

Adhesion within endodontic obturation material and root canal walls improves the efficacy of the endodontic treatment by establishing a barrier that inhibits reinfection and entombs residual bacteria. This study evaluates the push-out bond strength (POBS) of calcium silicate sealers compared to an epoxy-resin-based sealer. A total of 36 extracted mono-radicular teeth were prepared with Pro Taper Ultimate and irrigated with 5.

View Article and Find Full Text PDF

: This study aimed to investigate the fracture strength of a novel-designed Zirconia crown before and after access opening, and to evaluate the mode of fracture and the time needed for initial penetration through the crown. : This study involved the design and testing of 60 zirconia crowns, divided into three groups (20 crowns each) to compare different structural designs. Group 1 (Control) used a conventional full zirconia crown.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!