Are Volar Locking Plates Superior to Percutaneous K-wires for Distal Radius Fractures? A Meta-analysis.

Clin Orthop Relat Res

Division of Orthopaedic Surgery, McMaster University, 293 Wellington Street N, Suite 110, Hamilton, ON, L8L 8E7, Canada,

Published: September 2015

Background: Distal radius fractures are common, costly, and increasing in incidence. Percutaneous K-wire fixation and volar locking plates are two of the most commonly used surgical treatments for unstable dorsally displaced distal radius fractures. However, there is uncertainty regarding which of these treatments is superior.

Questions/purposes: We performed a meta-analysis of randomized controlled trials to determine whether patients treated with volar locking plates (1) achieved better function (2) attained better wrist motion, (3) had better radiographic outcomes, and (4) had fewer complications develop than did patients treated with K-wires for dorsally displaced distal radius fractures.

Methods: We performed a comprehensive search of MEDLINE (inception to 2014, October Week 2), EMBASE (inception to 2014, Week 42), and the Cochrane Central Register of Controlled Trials to identify relevant randomized controlled trials; we supplemented these searches with manual searches. We included studies of extraarticular and intraarticular distal radius fractures. Adjunctive external fixation was acceptable as long as the intent was to use only K-wires where possible and external fixation was used in less than 25% of the procedures. We considered a difference in the DASH scores of 10 as the minimal clinically important difference. We performed quality assessment with the Cochrane Risk of Bias tool and evaluated the strength of recommendations using the Grades of Recommendation, Assessment, Development and Evaluation (GRADE) approach. Seven randomized trials with a total of 875 participants were included in the meta-analysis.

Results: Patients treated with volar locking plates had slightly better function than did patients treated with K-wires as measured by their DASH scores at 3 months (mean difference [MD], 7.5; 95% CI, 4.4-10.6; p < 0.001) and 12 months (MD, 3.8; 95% CI, 1.2-6.3; p = 0.004). Neither of these differences exceeded the a priori-determined threshold for clinical importance (10 points). There was a small early advantage in flexion and supination in the volar locking plate group (3.7° [95% CI, 0.3°-7.1°; p = 0.04] and 4.1° [95% CI, 0.6°-7.6°; p = 0.02] greater, respectively) at 3 months, but not at later followups (6 or 12 months). There were no differences in radiographic outcomes (volar tilt, radial inclination, and radial height) between the two interventions. Superficial wound infection was more common in patients treated with K-wires (8.2% versus 3.2%; RR = 2.6; p = 0.001), but otherwise no difference in complication rates was found.

Conclusions: Despite the small number of studies and the limitations inherent in a meta-analysis, we found that volar locking plates show better DASH scores at 3- and 12-month followups compared with K-wires for displaced distal radius fractures in adults; however, these differences were small and unlikely to be clinically important. Further research is required to better delineate if there are specific radiographic, injury, or patient characteristics that may benefit from volar locking plates in the short term and whether there are any differences in long-term outcomes and complications.

Level Of Evidence: Level I, therapeutic study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4523532PMC
http://dx.doi.org/10.1007/s11999-015-4347-1DOI Listing

Publication Analysis

Top Keywords

volar locking
28
locking plates
24
distal radius
24
patients treated
20
radius fractures
16
displaced distal
12
controlled trials
12
treated k-wires
12
dash scores
12
volar
8

Similar Publications

BACKGROUND Extensor pollicis longus (EPL) tendon rupture is a potential complication following distal radius fracture, typically occurring several weeks after injury. Herein, we present a rare case of acute extensor pollicis longus tendon rupture associated with a distal radius fracture. CASE REPORT A 35-year-old woman visited our hospital with a distal radius fracture.

View Article and Find Full Text PDF

Introduction: Although there is no consensus in the literature, it is believed that the Soong classification system and fracture pattern are risk factors for plate removal in distal radius fractures.

Hypothesis: The aim of this large-scale study was to evaluate the relationship between Soong classification, fracture pattern, and implant removal in distal radius fractures.

Materials And Methods: We retrospectively evaluated 795 patients who underwent surgery using a volar locking plate for distal radius fractures at our clinic between 2005 and 2022.

View Article and Find Full Text PDF

There are many approaches to the wrist both volar and dorsal, depending on the injury at hand. The design of the volar locking plate has created a rise in distal radius fractures being treated using a volar FCR approach and its modifications. It does, however, have limitations in visualization of the volar ulnar corner of the radius.

View Article and Find Full Text PDF

Treatment of anterior rim fractures of the distal radius with an anterior rim plate: A retrospective study.

J Hand Surg Eur Vol

January 2025

Department of Orthopedics, E-Da Hospital, I-Shou University/School of Medicine, College of Medicine, I-Shou University, Kaohsiung, Taiwan.

Treatment of distal radial fractures that include small anterior rim fragments can be difficult. We retrospectively reviewed 19 patients in whom an anterior rim plate with locking screws was used. After a median follow-up of 18 months (range 6-32; interquartile range (IQR) 14, 26), the median wrist flexion and extension arc was 70° (range 50-80; IQR 60, 70), the median grip strength was 80% of the contralateral side (range 52-104; IQR 77, 88), the median visual analogue scale score for pain was 0 (range 0-5; IQR 0, 1), the median disabilities of the arm, shoulder and hand score was 2 (range 0-59; IQR 0, 11) and the median modified Mayo wrist score was 80 (range 35-100; IQR 75, 85).

View Article and Find Full Text PDF

Background: Extra-articular but severely comminuted distal basal fractures of the proximal phalanx (PP) are rarely reported. Therefore, the aim of this study was to achieve proper union and desirable outcomes using low-profile locking plates/screws. We introduced our own surgical approach and reported the clinical/radiographic outcomes via retrospective case series.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!