Background: Arthroplasty has been shown to be superior regarding low risk of reoperation and better function score to internal fixation for treatment of displaced femoral neck fractures at short-term followup. However, there are unanswered questions regarding the efficacy of arthroplasty in the longer term compared with internal fixation.
Questions/purposes: We performed a meta-analysis comparing arthroplasty (hemiarthroplasty or THA) with internal fixation in patients with displaced femoral neck fractures with respect to (1) mortality, (2) reoperation, (3) functional recovery, and (4) complications, including only randomized trials with a minimum of 4 years followup.
Methods: Computerized databases, including PubMed (MEDLINE), EMBASE, Cochrane Register of Controlled Trials databases, and Web of Science™ were searched for studies published from the inception date for each database to March 2014. Eleven randomized controlled trials that compared arthroplasty (either hemiarthroplasty or THA) with internal fixation for treatment of patients with a femoral neck fracture were included in our analysis. The quality of the trials was assessed according to the Cochrane Handbook and meta-analyses were conducted using RevMan 5.2 software from the Cochrane Collaboration. The heterogeneity among studies was evaluated by the I-squared index (I2) and publication bias was assessed using forest plots.
Results: There were no differences between the internal fixation and arthroplasty groups for patient mortality at mid-term (48.4% vs 46.8%) or long-term followup (83.2% vs 81.5%). Arthroplasty was associated with a lower risk of reoperation at mid-term (7.2% vs 39.8%; relative risk [RR]=0.10; 95% CI, 0.06-0.07) and at long-term followup (14.3% vs 43.8%; RR=0.10; 95% CI, 0.06-0.07). Arthroplasty was associated with better functional recovery at mid-term followup (standard mean difference [SMD]=0.55; 95% CI, 0.02-1.09), whereas function at long-term followup (SMD=0.14; 95% CI, -0.35 to 0.62) was not different between the arthroplasty and internal fixation groups. There were no significant differences in subsequent ipsilateral fractures (1.5% vs 1.2%; RR=2.18; 95% CI, 0.32-14.67; p=0.42) and deep infections (2.7% vs 2.9%; RR=0.89; 95% CI, 0.40-2.01; p=0.78) between patients treated with arthroplasty and internal fixation.
Conclusions: Based on our results, we found that compared with internal fixation, arthroplasty may result in a lower rate of subsequent reoperation at mid- and long-term followup, and better mid-term functional recovery. Future studies should investigate the mid- and long-term results of THAs compared with hemiarthroplasty.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4488202 | PMC |
http://dx.doi.org/10.1007/s11999-015-4345-3 | DOI Listing |
Eur J Orthop Surg Traumatol
January 2025
Department of Orthopaedic Surgery, University of California San Diego, 200 West Arbor Drive MC 8894, San Diego, CA, 92103, USA.
Purpose: While treatment modalities for Maisonneuve fractures involving the proximal third of the fibula are established, no studies to date have reported outcomes associated with syndesmotic-only fixation of middle third fibular shaft fractures. The purpose of this study was to evaluate outcomes associated with syndesmotic-only fixation in the treatment of Maisonneuve fractures involving the middle third of the fibula.
Methods: A retrospective review was conducted on 257 cases of syndesmotic ankle instability with associated fibular fractures at a level 1 trauma center between 2013 and 2023.
Arch Orthop Trauma Surg
January 2025
Department of Orthopedics and Traumatology, University Medical Center Mainz, Mainz, Germany.
Iliosacral screw osteosynthesis is a widely recognized technique for stabilizing unstable posterior pelvic ring injuries, offering notable advantages, including enhanced mechanical stability, minimal invasiveness, reduced blood loss, and lower infection rates. However, the procedure presents technical challenges due to the complex anatomy of the sacrum and the proximity of critical neurovascular structures. While conventional fluoroscopy remains the primary method for intraoperative guidance, precise preoperative planning using multiplanar reconstructions and three-dimensional volume rendering is crucial for ensuring accurate placement of iliosacral or transsacral screws.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Oral and Maxillofacial Surgery, University of Marburg, Baldingerstrasse, D-35043 Marburg, Germany.
During the routine removal of osteosynthesis materials after surgical treatment (ORIF) of condylar head fractures (CHFs), as performed at our clinic, localised and sometimes pronounced intra-articular scarring were observed quite regularly. This prospective study therefore investigates the causes of intra-articular scarring and its impact on functionality after surgical treatment (ORIF) of condylar head fractures (CHFs). Moreover, 80/98 patients with 96/114 CHFs (ORIF between 2014 and 2024) were evaluated when performing hardware removal.
View Article and Find Full Text PDFJ Clin Med
December 2024
Division of Maxillofacial Surgery, Surgical Science Department, Città della Salute e della Scienza Hospital, University of Turin, 10126 Turin, Italy.
: Mandibular fractures are among the most common facial injuries. Bilateral fractures of the mandibular body region (BBMFs), however, are rare. The aim of this retrospective study was to analyze the characteristics, surgical management, and outcomes of BBMFs in a third-level trauma center in northern Italy.
View Article and Find Full Text PDFBMC Musculoskelet Disord
January 2025
Department of Orthopedics, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 100045, China.
Background: Displaced tibial tubercle (TT) fractures in adolescents are typically treated with open reduction and internal fixation. While metallic screw (MS) fixation provides strong stability, it often results in a high incidence of postoperative screw head protrusion or irritation, leading to additional removal surgery. Bioabsorbable screw (BS) fixation presents an alternative that may avoid these issues, though its stability has not yet been extensively documented in the literature.