Purpose: A head-to-head comparison of two clinical correlation models with a focus on geometrical accuracy for internal tumor motion estimation during real-time tumor tracking (RTTT).
Methods And Materials: Both the CyberKnife (CK) and the Vero systems perform RTTT with a correlation model that is able to describe hysteresis in the breathing motion. The CK dual-quadratic (DQ) model consists of two polynomial functions describing the trajectory of the tumor for inhale and exhale breathing motion, respectively. The Vero model is based on a two-dimensional (2D) function depending on position and speed of the external breathing signal to describe a closed-loop tumor trajectory. In this study, 20 s of internal motion data, using an 11 Hz (on average) full fluoroscopy (FF) sequence, was used for training of the CK and Vero models. Further, a subsampled set of 15 internal tumor positions (15p) equally spread over the different phases of the breathing motion was used for separate training of the CK DQ model. Also a linear model was trained using 15p and FF tumor motion data. Fifteen liver and lung cancer patients, treated on the Vero system with RTTT, were retrospectively evaluated comparing the CK FF, CK 15p and Vero FF models using an in-house developed simulator. The distance between estimated target position and the tumor position localized by X-ray imaging was measured in the beams-eye view (BEV) to calculate the 95th percentile BEV modeling errors (ME(95,BEV)). Additionally, the percentage of ME(95,BEV) smaller than 5 mm (P(5mm)) was determined for all correlation models.
Results: In general, no significant difference (p>0.05, paired t-test) was found between the CK FF and Vero models. Based on patient-specific evaluation of the geometrical accuracy of the linear, CK DQ and Vero correlation models, no statistical necessity (p>0.05, two-way ANOVA) of including hysteresis in correlation models was proven, although during inhale breathing motion, the linear model resulted in a decreased P(5mm) with 5-6% compared to both the DQ CK and Vero models.
Conclusion: Dual-quadratic CyberKnife and 2D Vero correlation models were interchangeable in terms of geometrical accuracy with the CK linear ME(95,BEV)=4.1 mm, CK dual-quadratic ME(95,BEV)=3.9 mm and Vero ME(95,BEV)=3.7 mm, when modeled with FF sequence. CK DQ modeling based on 15p acquired in 20 s may lead to problems for internal motion estimation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.radonc.2015.05.004 | DOI Listing |
Viruses
November 2024
Department of Infectious Diseases, Molecular Virology, Section Virus-Host Interactions, Heidelberg University, 69120 Heidelberg, Germany.
The study of hepatitis C virus (HCV) replication in cell culture is mainly based on cloned viral isolates requiring adaptation for efficient replication in Huh7 hepatoma cells. The analysis of wild-type (WT) isolates was enabled by the expression of SEC14L2 and by inhibitors targeting deleterious host factors. Here, we aimed to optimize cell culture models to allow infection with HCV from patient sera.
View Article and Find Full Text PDFVaccines (Basel)
November 2024
Vaccine Research and Development, Pfizer Inc., Pearl River, NY 10965, USA.
Background/objectives: Respiratory syncytial virus (RSV) is the leading cause of severe respiratory disease in infants worldwide. Maternal immunization to protect younger infants is supported by evidence that virus-neutralizing antibodies, which are efficiently transferred across the placenta from mother to fetus, are a primary immune mediator of protection. In maternal RSV vaccine studies, estimates of correlates of protection are elusive because many factors of maternal-fetal immunobiology and disease characteristics must be considered for the estimates.
View Article and Find Full Text PDFSensors (Basel)
December 2024
College of Civil Engineering and Architecture, Xiamen University of Technology, Xiamen 361024, China.
This study presents a comprehensive method for detecting debonding defects in concrete-filled steel tube (CFST) structures using wave propagation analysis with externally attached piezoelectric ceramic sensors. Experimental tests and numerical simulations were conducted to evaluate the sensitivity and accuracy of two measurement techniques-the flat and oblique measurement methods-in detecting debonding defects of varying lengths and heights. The results demonstrate that the flat measurement method excels in detecting debonding height, while the oblique method is more effective for detecting debonding length.
View Article and Find Full Text PDFSensors (Basel)
December 2024
NUS-ISS, National University of Singapore, Singapore 119615, Singapore.
The attention mechanism is essential to (CNN) vision backbones used for sensing and imaging systems. Conventional attention modules are designed heuristically, relying heavily on empirical tuning. To tackle the challenge of designing attention mechanisms, this paper proposes a novel probabilistic attention mechanism.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Automation, Xiamen University, Xiamen 361102, China.
Recent advancements in the field of object tracking have been notably influenced by Siamese-based trackers, which have demonstrated considerable progress in their performance and application. Researchers frequently emphasize the precision of trackers, yet they tend to neglect the associated complexity. This oversight can restrict real-time performance, rendering these trackers inadequate for specific applications.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!