We present a novel method of quickly acquiring dermal interstitial fluid (ISF) samples using a Lorentz-force actuated needle-free jet injector. The feasibility of the method is first demonstrated on post-mortem porcine tissue. The jet injector is used to first inject a small volume of physiological saline to breach the skin, and the back-drivability of the actuator is utilized to create negative pressure in the ampoule and collect ISF. The effect of the injection and extraction parameters on sample dilution and extracted volumes is investigated. A simple finite element model is developed to demonstrate why this acquisition method results in faster extractions than conventional sampling methods. Using this method, we are able to collect a sample that contains up to 3.5% ISF in 3.1s from post-mortem skin. The trends revealed from experimentation on post-mortem skin are then used to identify the parameters for a live animal study. The feasibility of the acquisition process is successfully demonstrated using live rats; the process is revealed to extract samples that have been diluted by a factor of 111-125.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jconrel.2015.05.264 | DOI Listing |
Flow Turbul Combust
November 2024
Institut de Mécanique des Fluides de Toulouse, IMFT, CNRS, Université de Toulouse, Toulouse, France.
Improving mixing between two coaxial swirled jets is a subject of interest for the development of next generations of fuel injectors. This is particularly crucial for hydrogen injectors, where the separate introduction of fuel and oxidizer is preferred to mitigate the risk of flashback. Raman scattering is used to measure the mean compositions and to examine how mixing between fuel and air streams evolves along the axial direction in the near-field of the injector outlet.
View Article and Find Full Text PDFVaccines (Basel)
January 2025
State Research Center of Virology and Biotechnology "Vector", Rospotrebnadzor, World-Class Genomic Research Center for Biological Safety and Technological Independence, Federal Scientific and Technical Program on the Development of Genetic Technologies, 630559 Koltsovo, Russia.
Although mRNA vaccines encapsulated in lipid nanoparticles (LNPs) have demonstrated a safety profile with minimal serious adverse events in clinical trials, there is opportunity to further reduce mRNA reactogenicity. The development of naked mRNA vaccines could improve vaccine tolerability. Naked nucleic acid delivery using the jet injection method may be a solution.
View Article and Find Full Text PDFSci Rep
January 2025
Faculty of Mechanical Engineering, University of Tabriz, Tabriz, Iran.
This investigation presents extensive computational analyses of the compressible flow near ramp injector with double circular injectors at supersonic combustor of scramjet engine. Comparison of the fuel mixing and fuel jet penetration of hydrogen jet are done for two injector configurations at free stream Mach number of 2. The simulation of the supersonic flow near ramp injector is done via solving RANS equations with computational fluid dynamic technique.
View Article and Find Full Text PDFCell Biosci
December 2024
Department of Pathology, Johns Hopkins School of Medicine, CRB II Room 307, 1550 Orleans St, Baltimore, MD, USA.
Background: We have previously developed a candidate therapeutic HPV DNA vaccine (pBI-11) encoding mycobacteria heat shock protein 70 linked to HPV16/18 E6/E7 proteins for the control of advanced HPV-associated oropharyngeal cancer (NCT05799144). While naked DNA vaccines are readily produced, stable, and well tolerated, their potency is limited by the delivery efficiency. Here we compared three different IM delivery strategies, including intramuscular (IM) injection, either with a needle alone or with electroporation at the injection site, and a needle-free injection system (NFIS), for their ability to elicit gene expression and to improve the potency of pBI-11 DNA vaccine.
View Article and Find Full Text PDFAnn Dermatol
December 2024
Department of Dermatology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Korea.
Background: Botulinum toxin is commonly used for cosmetic enhancements in various applications. However, the pain experienced during the injection process remains a significant concern.
Objective: This study aimed to evaluate the effectiveness and safety of a needle-free microjet drug injector, powered by an Er:YAG laser, for the injection of botulinum toxin to treat crow's feet wrinkles.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!