A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Electrospun polymer nanofibres as solid-phase extraction sorbents for extraction and quantification of microcystins. | LitMetric

Electrospun polymer nanofibres as solid-phase extraction sorbents for extraction and quantification of microcystins.

Environ Technol

a Key Laboratory of Environmental Medicine Engineering of Ministry of Education , School of Public Health, Southeast University, Nanjing 210009 , People's Republic of China.

Published: June 2016

Electrospun polymer nanofibres were used as novel solid-phase extraction (SPE) sorbents to extract and quantify the microcystins (MCs) including microcystin-RR (MC-RR) and microcystin-LR (MC-LR) from in-suit water samples. The parameters that influenced the extraction efficiency were studied, including the amount of nanofibre, eluted solvent, eluted volume, pH, and the water sample volume. Under optimized conditions, a linear response for MC-RR and MC-LR over the range of 0.25-4 µg/L was achieved with r(2) values of 0.998 and 0.997, respectively. The extraction recovery of MC-RR and MC-LR was 97-102% and 98-100%, respectively, when the MC concentration was 0.25-4 µg/L. When their concentrations ranged from 0.05  to 0.25 µg/L, the MCs could be detected with high accuracy by the nanofibre SPE sorbent combined with nitrogen gas. Due to its simplicity, environment-friendliness, high efficiency, reusability, and sensitivity, the electrospun polymer nanofibre can be applied as a novel SPE sorbent to extract and detect the MCs from in-suit water samples.

Download full-text PDF

Source
http://dx.doi.org/10.1080/09593330.2015.1049213DOI Listing

Publication Analysis

Top Keywords

electrospun polymer
12
polymer nanofibres
8
solid-phase extraction
8
in-suit water
8
water samples
8
mc-rr mc-lr
8
spe sorbent
8
extraction
5
nanofibres solid-phase
4
extraction sorbents
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!