A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of pachymetry measurements between the Alcon Wavelight EX500 and Sonogage Corneo-Gage plus platforms. | LitMetric

Purpose: To compare the agreement of intraoperative central corneal thickness (CCT) measurements of the Wavelight EX500 (Alcon Laboratories, Fort Worth, TX) that uses optical low coherence reflectometry to the Corneo-Gage Plus ultrasound pachymetry device (Sonogage, Cleveland, OH).

Methods: In this retrospective study, 50 eyes of 26 patients undergoing LASIK were evaluated. Following LASIK flap creation, each eye was measured by both optical low coherence reflectometry and ultrasound pachymetry immediately prior to flap lifting and then again after flap lifting.

Results: The mean CCT value before lifting the flap was 556.9 and 557.78 µm as measured by ultrasound pachymetry and optical low coherence reflectometry, respectively. After lifting the flap, the mean ultrasound pachymetry value was 440.96 µm and the mean optical low coherence reflectometry value was 441.7 µm. A two-sample Kolmogorov-Smirnov test demonstrated that the ultrasound pachymetry and the optical low coherence reflectometry distribution of measurements were the same. A Shapiro-Wilk test of normality could not be rejected. Bland-Altman plots showed strong agreement. The correlation between the two tests was 0.98 before flap lifting and 0.97 after flap lifting, both with a 95% confidence interval.

Conclusions: The pachymetry measurements by the optical low coherence reflectometry correlated with those of the ultrasound pachymetry device. The Wavelight EX500 optical low coherence reflectometry may be used in place of the ultrasound pachymetry device for measuring CCT.

Download full-text PDF

Source
http://dx.doi.org/10.3928/1081597X-20150423-06DOI Listing

Publication Analysis

Top Keywords

optical low
28
low coherence
28
coherence reflectometry
28
ultrasound pachymetry
28
wavelight ex500
12
pachymetry device
12
flap lifting
12
lifting flap
12
pachymetry measurements
8
pachymetry
8