The close proximity of the infraspinatus to the teres minor and their functional similarity in producing external rotation of the glenohumeral joint make accurate insertion of electromyographic (EMG) electrodes into the teres minor difficult and questionable even when published guidelines are followed. The primary aim of this study was to examine the anatomical support for the current guidelines for inserting intramuscular EMG electrodes into the teres minor muscle. The secondary aim was to provide a technical description for ultrasound-guided electrode insertion into the teres minor. Intramuscular electrodes were inserted into four cadaveric shoulders using markings based on the current guidelines. EMG electrodes were also inserted into the teres minor of four healthy male participants using real-time ultrasound (RTUS) guidance. Systematic dissections of the cadaver specimens revealed that the electrode had been successfully inserted into the teres minor muscle in only one out of the four. In the remaining three specimens, the needle lodged in the infraspinatus muscle belly at distances ranging from 3 to 17 mm medial to the teres minor. Using RTUS guidance, the electrodes were successfully inserted into the teres minor in all participants, as confirmed by visual inspection with RTUS. This study confirms that the current EMG electrode insertion guidelines for the teres minor are not accurate and RTUS ensures the placement of electrodes into the teres minor rather than the adjacent infraspinatus muscle.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ca.22561 | DOI Listing |
Acta Orthop Traumatol Turc
December 2024
Department of Orthopedics, !e Second People's Hospital of Xiangcheng District, Suzhou, China.
Objective: The aim of this study was to examine if tranexamic acid (TXA) can assist in improving outcomes of arthroscopic rotator cu! repair (RCR).
Methods: The databases of PubMed, Embase, Web of Science, CENTRAL, and Scopus were searched for all types of studies examining the e"cacy of TXA for arthroscopic RCR. Twelve studies, 10 randomized controlled trials (RCTs), and 2 retrospective studies were considered eligible.
JSES Rev Rep Tech
February 2025
Clinique Claude Bernard, Unité de Chirurgie Orthopédique, Metz, France.
Background: The importance of the subscapularis for reverse total shoulder arthroplasty has been demonstrated, especially for internal rotation and stability. In a deltopectoral approach, a detachment of the subscapularis is performed (tenotomy, tuberosity peeling, or osteotomy), but the tendon is not always repairable at the end. When it is repaired, healing is obtained in only 40%-76% of the cases, with potential consequences for the outcomes.
View Article and Find Full Text PDFJSES Rev Rep Tech
February 2025
Department of Orthopaedics, University of Utah, Salt Lake City, UT, USA.
Background: To perform an analysis of intraoperative costs associated with arthroscopic rotator cuff repair (RCR) acellular dermal allograft patch augmentation and interposition.
Methods: This was a matched cohort retrospective cost identification analysis. We identified patients who underwent arthroscopic RCR with acellular dermal allograft patch augmentation or interposition between 2014 and 2023 at a single academic center.
JSES Rev Rep Tech
February 2025
Department of Orthopaedic Surgery, Yeosu Baek Hospital, Jeollanam-do, Republic of Korea.
JSES Rev Rep Tech
February 2025
Smith & Nephew, Asia Pacific, Singapore, Singapore.
Background: In patients with rotator cuff tears (RCTs), there is a lack of evidence regarding the impact of the timeliness of rotator cuff repair (RCR) surgery on treatment outcomes and overall healthcare burden. This study aimed to understand the impact of early vs. delayed RCR on real-world healthcare costs and resource use (HCRU) in Japan.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!