A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Impact of clinical follow-up and diagnostic testing on intervention for tetralogy of Fallot. | LitMetric

Objective: Our purpose was to evaluate yield of tools commonly advocated for surveillance of tetralogy of Fallot (TOF).

Methods: All patients (pts) with TOF, seen at any time from 1/2008 to 9/2013 in an academic cardiology practice were studied. At the first and each subsequent outpatient visit, the use of tools including history and physical (H&P), ECG, Holter (HOL), echocardiogram (Echo), MR or CT (MR-CT) and stress testing (STR) were noted. Recommendations for intervention (INT) and for time to next follow-up were recorded; rationale for each INT with attribution to one or more tools was identified.

Results: There were 213 pts (mean 11.5 years, 130 male) who had 916 visits, 123 of which (13.4%) were associated with 138 INTs (47 surgical, 54 catheter-mediated, 37 other medical). Recommended follow-up interval was 9.44±6.5 months, actual mean follow-up interval was 11.7 months. All 916 (100%) patient visits had a H&P which contributed to 47.2% of INT decisions. Echo was performed in 652 (71.2%) of visits, and contributed to 53.7% of INTs. MR-CT was obtained in 129 (14.1%) of visits, and contributed to 30.1% of INTs. ECG was applied in 137 (15%) visits, and contributed to 1.6% of INTs. HOL was obtained in 188 (20.5%) visits, and contributed to 11.3% of INTs. STR was performed at 101 (11%) of visits, and contributed to 8.9% of INTs.

Conclusions: INTs are common in repaired TOF, but when visits average every 11-12 months, most visits do not result in INT. H&P, Echo and HOL were the most frequently applied screens, and all frequently yielded relevant information to guide INT decisions. STR and MR/CT were applied as targeted testing and in this limited, non-screening role had high relevance for INT. There was low utilisation of ECG and major impact on INT was not demonstrated. Risk stratification in TOF may be possible, and could result in more efficient surveillance and targeted testing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4422920PMC
http://dx.doi.org/10.1136/openhrt-2014-000185DOI Listing

Publication Analysis

Top Keywords

visits contributed
20
visits
9
tetralogy fallot
8
follow-up interval
8
int decisions
8
targeted testing
8
int
7
ints
6
contributed
6
impact clinical
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!