Reduced limb length discrepancy and more accurate cup positioning are purported benefits of using fluoroscopy for total hip arthroplasty (THA). The authors compared limb length discrepancy and cup position in 200 patients (group I, posterior approach without fluoroscopy; group II, anterior supine approach with fluoroscopy) who underwent primary THA. Mean limb length discrepancy was 2.7 mm (SD, 5.2 mm; range, -9.8 to 20.9 mm) and 0.7 mm (SD, 3.7 mm; range, -11.8 to 10.5 mm) for groups I and II, respectively (P=.002). In group I, 7% of hips had limb length discrepancy greater than 1 cm compared with 3% in group II. Mean cup inclination measured 40.8° (SD, 5.0°; range, 26.1°-53.7°) in group I and 43.4° (SD, 5.6°; range, 31.3°-55.9°) in group II (P=.008). In group I, 96% of cups had inclination within 10° of the mean compared with 92% in group II (P=.24). Mean anteversion measured 35.3° (SD, 7.1°; range, 17.8°-60.7°) in group I and 25.9° (SD, 8.2°; range, 1.5°-44.8°) in group II (P=.0001). In group I, 87% of hips exhibited anteversion within 10° of the mean compared with 76% in group II (P=.045). Although the anterior approach with intraoperative fluoroscopy reduced mean limb length discrepancy, the clinical significance of this reduction is unclear. Fluoroscopy reduced the incidence of limb length discrepancy greater than 1 cm. However, the use of fluoroscopy did not help to improve the precision of cup positioning.

Download full-text PDF

Source
http://dx.doi.org/10.3928/01477447-20150504-54DOI Listing

Publication Analysis

Top Keywords

limb length
28
length discrepancy
24
group
12
intraoperative fluoroscopy
8
reduced limb
8
cup positioning
8
approach fluoroscopy
8
discrepancy greater
8
10° compared
8
fluoroscopy reduced
8

Similar Publications

Introduction: One anastomosis gastric bypass (OAGB) is a common procedure associated with satisfactory outcomes. Revisional surgery due to weight regain or insufficient weight loss (WR/IWL) after OAGB is underreported.

Methods: A retrospective analysis of a single-bariatric surgeon database was conducted.

View Article and Find Full Text PDF

Introduction: Salvage arthroplasty for failed proximal femoral fracture fixation is a complex procedure. This involves the removal of the primary failed or broken implant followed by a hip joint replacement procedure. The complications and technical difficulties associated with these surgeries are often difficult to anticipate.

View Article and Find Full Text PDF

 Reduction of very huge breast-gigantic macromastia-is a challenge to breast surgeons in choosing the right procedure to obtain an optimal outcome. The feasibility of a superomedial pedicle (SMP) with some modifications proves to be a good option to achieve a viable nipple areolar complex (NAC) with good size and shape after good resection above 800 g.  Out of the 35 patients with 70 breast reductions, 15 can be considered gigantic macromastia with reductions above 800 g.

View Article and Find Full Text PDF

Purpose: To assess the safety and efficacy of flush endovenous laser ablation (fEVLA) in the treatment of chronic venous insufficiency.

Materials And Methods: Following the PRISMA 2020 guidelines, a systematic review aiming to identify studies published from inception to March 2024 was conducted. The investigation covered single-arm studies and studies comparing fEVLA to standard EVLA (sEVLA).

View Article and Find Full Text PDF

Introduction: Roux-en-Y gastric bypass (RYGB) reversal might be necessary to alleviate refractory surgical or nutritional complications, such as postprandial hypoglycemia, malnutrition, marginal ulceration, malabsorption, chronic diarrhea, nausea and vomiting, gastro-esophageal reflux disease, chronic pain, or excessive weight loss. The surgical technique of RYGB reversal is not standardized; potential strategies include the following: (1) gastro-gastrostomy: hand-sewn technique, linear stapler, circular stapler; (2) handling of the Roux limb: reconnection or resection (if remaining intestinal length ≥ 4 m).

Case Presentation: We demonstrate the surgical technique of a laparoscopic reversal of RYGB with hand-sewn gastro-gastrostomy and resection of the alimentary limb with the aim of improving the patient's quality of life.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!