A femtosecond pulse train with THz repetition rate generated by the interference of two phase-modulated pulses has been recorded experimentally. Pulse repetition rates and their duration have been measured. It has been shown that at the 50-fs time delay between phase-modulated pulses the repetition rate is 3.1 THz with a pulse width of 200 fs, while at the 120-fs time delay the repetition rate is 7.1 THz with a pulse width of 67 fs.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.54.002113DOI Listing

Publication Analysis

Top Keywords

repetition rate
16
femtosecond pulse
8
pulse train
8
train thz
8
thz repetition
8
rate generated
8
generated interference
8
interference phase-modulated
8
phase-modulated pulses
8
time delay
8

Similar Publications

Motlagh, JG and Lipps, DB. The contribution of muscular fatigue and shoulder biomechanics to shoulder injury incidence during the bench press exercise: A narrative review. J Strength Cond Res 38(12): 2147-2163, 2024-Participation in competitive powerlifting has rapidly grown over the past two decades.

View Article and Find Full Text PDF

Anion photoelectron velocity-map imaging using a tunable laser at a 100 kHz repetition rate.

J Chem Phys

January 2025

Department of Chemistry, Faculty of Science, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan.

We present velocity-map imaging (VMI) of photoelectrons detached from anions using an optical parametric amplifier operating at a repetition rate as high as 100 kHz. The light source generates femtosecond (fs) laser pulses tunable from near-infrared to ultraviolet (310-2600 nm), which interact synchronously with mass-selected anion bunches. We demonstrate this technique by measuring two-dimensional projections of photoelectrons ejected from silver trimer anions, Ag3-, across a photon energy range from 2.

View Article and Find Full Text PDF

Purpose: Currently available grading and classification systems for hemifacial spasm either rely on subjective assessments or are excessively intricate. Here, we make use of facial recognition and facial tracking technologies towards accurately grouping patients according to severity and characteristics of the spasms.

Methods: A retrospective review of our prospectively maintained preoperative videos database for hemifacial spasm was done.

View Article and Find Full Text PDF

Serial macromolecular crystallography has become a powerful method to reveal room temperature structures of biological macromolecules and perform time-resolved studies. ID29, a flagship beamline of the ESRF 4th generation synchrotron, is the first synchrotron beamline in the world capable of delivering high brilliance microsecond X-ray pulses at high repetition rate for the structure determination of biological macromolecules at room temperature. The cardinal combination of microsecond exposure times, innovative beam characteristics and adaptable sample environment provides high quality complete data, even from an exceptionally small amount of crystalline material, enabling what we collectively term serial microsecond crystallography (SµX).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!