Background And Purpose: We assessed whether intentional undersized dilatation of targeted lesions during carotid artery stenting (CAS) carried a higher risk of in-stent restenosis (ISR) and correlation to subsequent ischemic stroke in qualifying arteries in the follow-up period.

Methods: Consecutive patients undergoing CAS between April 2003 and May 2010 were retrospectively reviewed. The use of a filter device as a distal embolic protection device (EPD) was first approved by Japanese governmental health insurance in April 2008; previously, transient balloon occlusion was used off-label. Until March 2008 (Group A), the target diameter of balloon dilatation was 80-100% of the normal vessel diameter just distal to the stenotic lesion. Moderately undersized dilatation (70-80% of the normal vessel diameter) using the distal EPD was adopted in April 2008 (Group B) in an attempt to reduce the amount of released plaque debris.

Results: We analyzed 132 CAS procedures (125 patients) in Group A and 53 CAS procedures (52 patients) in Group B. The mean follow-up period was 35.4 months (35.3 months in Group A and 36.0 months in Group B). Eight lesions (4.3%; 7 in Group A and 1 in Group B) developed ISR. None of the patients had symptomatic ISR, and ISR did not increase in Group B (odds ratio, 0.34; 95% confidence interval, 0.04-2.86; p = 0.32).

Conclusions: Undersized dilatation of targeted lesions did not increase the risk of developing ISR, and we suggest it as a viable treatment option to prevent ischemic events during CAS.

Download full-text PDF

Source
http://dx.doi.org/10.3109/02688697.2015.1029430DOI Listing

Publication Analysis

Top Keywords

undersized dilatation
16
dilatation targeted
12
targeted lesions
12
group
9
lesions carotid
8
carotid artery
8
artery stenting
8
april 2008
8
2008 group
8
normal vessel
8

Similar Publications

Purpose: Valve-sparing root replacement (VSRR) is attractive for aortic root dilation as it preserves the native aortic valve (AoV). Low effective height (eH) after reconstruction is a risk factor for repair failure and reoperation. We developed and validated a quantitative AoV repair strategy to reliably restore normal valve proportions to promote long-term function.

View Article and Find Full Text PDF

TABERNACL: Temporary Hemodynamic Stabilization In Vivo.

Circ Cardiovasc Interv

May 2024

Cardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD (R.H., K.Y., D.U., A.E.J., L.P.G., R.J.L.).

Background: Acute aortic regurgitation is life-threatening with few nonsurgical options for immediate stabilization. We propose Trans-Aortic Balloon to Ease Regurgitation Applying Counter-Pulsation (TABERNACL), a simple, on-table temporary valve using commercially available equipment to temporize acute severe aortic regurgitation.

Methods: We hypothesize that an appropriately sized commercial balloon dilatation catheter-straddling the aortic annulus and connected to a counterpulsation console-can serve as a temporizing valve to restore hemodynamic stability in acute aortic regurgitation.

View Article and Find Full Text PDF

We aimed to develop a large animal model of subcoronary aortic stenosis (AS) to study intracoronary and microcirculatory hemodynamics. A total of three surgical techniques inducing AS were evaluated in 12 sheep. Suturing the leaflets together around a dilator ( = 2) did not result in severe AS.

View Article and Find Full Text PDF

Objectives: Optimal aortic sizing during aortic arch reconstruction remains unknown. Negative effects of arch under- or oversizing are well-published. We aimed to characterize longitudinal aortic growth after patch-augmented arch reconstruction to identify the initial reconstructed arch size that results in normal mid-term arch dimensions.

View Article and Find Full Text PDF

Predicted heart mass ratio (PHMr) has been proposed as an optimal size metric in the selection of a donor heart for transplant; however, it is not known if the same size matching criteria pertains uniformly to all types of cardiomyopathies. Heart transplant recipients in the United Network for Organ Sharing registry database were categorized into 6 groups based on the type of cardiomyopathy, dilated, coronary artery disease, hypertrophic, restrictive, valvular and adult congenital heart disease. Patients in each group of etiology were stratified based on the PHMr into 5 groups: severely undersized <0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!