In the present study, a straightforward approach was validated for the analysis of pharmaceutically active compounds and endocrine-disrupting chemicals in the mollusk tissues, with a focus on two species commonly consumed in Southeast Asia (green mussels: Perna viridis; lokan clams: Polymesoda expansa). This approach relied on a simple solvent extraction (shaker table) followed by direct injection in liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). This "cleanup-free" approach was made possible by the use of isotopically labeled surrogates (to correct for matrix effects) and a post-column switch on the LC-MS/MS system (to remove potential interfering material). Altogether, relative recoveries were satisfactory for 36 out of 44 compounds (26-163% range) and excellent for 27 out of 44 compounds (79-107% range). Method detection limits (MDLs) were usually expressed in the nanogram per gram wet weight (ww) range and below. The method was successfully applied to 16 batches of green mussel samples collected in Singapore coastal waters. Trace levels of six compounds were detected in mussel tissues: caffeine (0.22-1.55 ng g(-1) ww), carbamazepine (

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-015-8760-9DOI Listing

Publication Analysis

Top Keywords

direct injection
8
mass spectrometry
8
range method
8
injection tissue
4
tissue extracts
4
extracts liquid
4
liquid chromatography/tandem
4
chromatography/tandem mass
4
spectrometry determination
4
determination pharmaceuticals
4

Similar Publications

Purpose: Prior sperm DNA fragmentation index (DFI) thresholds for diagnosing male infertility and predicting assisted reproduction technology (ART) outcomes fluctuated between 15 and 30%, with no agreed standard. This study aimed to evaluate the impact of the sperm DFI on early embryonic development during ART treatments and establish appropriate DFI cut-off values.

Methods: Retrospectively analyzed 913 couple's ART cycles from 2021 to 2022, encompassing 1,476 IVF and 295 ICSI cycles, following strict criteria.

View Article and Find Full Text PDF

Objectives: Injection laryngoplasty (IL) is commonly performed for glottic insufficiency and has historically been performed under general anesthesia via direct laryngoscopy (DL), with an increasing number of procedures being performed in the office setting via flexible laryngoscopy (FL). Existing literature regarding complications of IL primarily addresses immediate peri-procedural complications and adverse reactions to the injection material. This is the first study utilizing a large multi-institutional database comparing complications of IL performed via DL versus FL.

View Article and Find Full Text PDF

The Rift Valley fever virus (RVFV) causes haemorrhagic fever, encephalitis, and permanent blindness and has been listed by the WHO as a priority pathogen. To study RVFV pathogenesis and identify small-molecule antivirals, we established a novel In Vivo model using zebrafish larvae. Pericardial injection of RVFV resulted in ~4 log viral RNA copies/larva, which was inhibited by the antiviral 2'-fluoro-2'-deoxycytidine.

View Article and Find Full Text PDF

Thymoglobulin is used to prevent allograft rejection and is being explored at low doses as intervention immunotherapy in type 1 diabetes. Thymoglobulin consists of a diverse pool of rabbit antibodies directed against many different targets on human thymocytes that can also be expressed by other leukocytes. Since Thymoglobulin is generated by injecting rabbits with human thymocytes, this conceivably leads to differences between Thymoglobulin batches.

View Article and Find Full Text PDF

Microfluidic Integration of Magnetically Functionalized Microwires for Flow Cytometry Protein Quantification.

Materials (Basel)

January 2025

Life Sciences Division, National Research Council of Canada, 75 de Mortagne Boulevard, Boucherville, QC J4B 6Y4, Canada.

A novel approach to protein quantification utilizing a microfluidic platform activated by a magnetic assembly of functionalized magnetic beads around soft magnetic capture centers is presented. Functionalized magnetic beads, known for their high surface area and facile manipulation under external magnetic fields, are injected inside microfluidic channels and immobilized magnetically on the surface of glass-coated soft magnetic microwires placed along the symmetry axis of these channels. A fluorescent (Cy5) immunomagnetic sandwich ELISA is then performed by sequentially flowing the sample and all necessary reagents in the microfluidic channels.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!