The inaccuracy of routine serum 25-hydroxyvitamin D measurements hampers the interpretation of data in patient care and public health research. We developed and validated a candidate reference measurement procedure (RMP) for highly accurate quantitation of two clinically important 25-hydroxyvitamin D metabolites in serum, 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3]. The two compounds of interest together with spiked deuterium-labeled internal standards [d 3-25(OH)D2 and d 6-25(OH)D3] were extracted from serum via liquid-liquid extraction. The featured isotope-dilution LC-MS/MS method used reversed-phase chromatography and atmospheric pressure chemical ionization in positive ion mode. A pentafluorophenylpropyl-packed UHPLC column together with isocratic elution allowed for complete baseline resolution of 25(OH)D2 and 25(OH)D3 from their structural C-3 isomers within 12 min. We evaluated method trueness, precision, potential interferences, matrix effects, limits of quantitation, and measurement uncertainty. Calibration materials were, or were traceable to, NIST Standard Reference Materials 2972. Within-day and total imprecision (CV) averaged 1.9 and 2.0% for 25(OH)D3, respectively, and 2.4 and 3.5% for 25(OH)D2, respectively. Mean trueness was 100.3% for 25(OH)D3 and 25(OH)D2. The limits of quantitation/limits of detection were 4.61/1.38 nmol/L for 25(OH)D3 and 1.46/0.13 nmol/L for 25(OH)D2. When we compared our RMP results to an established RMP using 40 serum samples, we found a nonsignificant mean bias of 0.2% for total 25(OH)D. This candidate RMP for 25(OH)D metabolites meets predefined method performance specifications (≤5% total CV and ≤1.7% bias) and provides sufficient sample throughput to meet the needs of the Centers for Disease Control and Prevention Vitamin D Standardization Certification Program. Graphical abstract Bias assessment using NIST standard reference materials. Legend CDC mean mass fractions (ng/g) ± U 95 (6 replicates per mean). NIST-certified mass fractions (ng/g) ± U 95 from the Certificates of Analysis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4823009PMC
http://dx.doi.org/10.1007/s00216-015-8733-zDOI Listing

Publication Analysis

Top Keywords

candidate reference
8
reference measurement
8
measurement procedure
8
serum 25-hydroxyvitamin
8
nist standard
8
standard reference
8
reference materials
8
mass fractions
8
fractions ng/g
8
25-hydroxyvitamin
6

Similar Publications

Transgender individuals commonly feel significant distress and discomfort, termed gender dysphoria, as a result of the discrepancy between their gender assigned at birth and their gender identity. A major source of gender dysphoria stems from distinct anatomical differences between the male and female chest. Gender-affirming mastectomy of transmasculine patients and breast augmentation for chest feminization of transfeminine patients, also referred to as top surgery, are often the first surgical interventions and most commonly pursued physical modifications for the treatment of gender dysphoria among this patient population.

View Article and Find Full Text PDF

The increasing utilization of deep learning models in drug repositioning has proven to be highly efficient and effective. In this study, we employed an integrated deep-learning model followed by traditional drug screening approach to screen a library of FDA-approved drugs, aiming to identify novel inhibitors targeting the TNF-α converting enzyme (TACE). TACE, also known as ADAM17, plays a crucial role in the inflammatory response by converting pro-TNF-α to its active soluble form and cleaving other inflammatory mediators, making it a promising target for therapeutic intervention in diseases such as rheumatoid arthritis.

View Article and Find Full Text PDF

Large Language Models in Worldwide Medical Exams: Platform Development and Comprehensive Analysis.

J Med Internet Res

December 2024

Joint Laboratory of Artificial Intelligence for Critical Care Medicine, Department of Critical Care Medicine and Institutes for Systems Genetics, Frontiers Science Center for Disease-related Molecular Network, West China Hospital, Sichuan University, Chengdu, China.

Background: Large language models (LLMs) are increasingly integrated into medical education, with transformative potential for learning and assessment. However, their performance across diverse medical exams globally has remained underexplored.

Objective: This study aims to introduce MedExamLLM, a comprehensive platform designed to systematically evaluate the performance of LLMs on medical exams worldwide.

View Article and Find Full Text PDF

Computer-aided design of caffeic acid derivatives: free radical scavenging activity and reaction force.

J Mol Model

December 2024

Departamento de Química, Universidad Autónoma Metropolitana-Iztapalapa, Avenida Ferrocarril San Rafael Atlixco, Número 186, Colonia Leyes de Reforma 1A Sección, Alcaldía Iztapalapa, Código Postal 09310, Ciudad de Mexico, Mexico.

Context: Antioxidants are known to play a beneficial role in human health. Caffeic acid has been previously recognized as efficient in this context. However, such a capability can be enhanced through structural modification.

View Article and Find Full Text PDF

Distinctive molecular approaches and tools, particularly high-throughput SNP genotyping, have been applied to determine and discover SNPs, potential genes of interest, indicators of evolutionary selection, genetic abnormalities, molecular indicators, and loci associated with quantitative traits (QTLs) in various livestock species. These methods have also been used to obtain whole-genome sequencing (WGS) data, enabling the implementation of genomic selection. Genomic selection allows for selection decisions based on genomic-estimated breeding values (GEBV).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!