Existing mammographic screening solutions are generally associated with several major drawbacks, such as exposure to ionizing radiation or insufficient sensitivity in younger populations with radiographically-dense breast. Even when combined with ultrasound or magnetic resonance imaging, X-Ray mammography may still attain unspecific or false positive results. Thus, development of new breast imaging tools represents a timely medical challenge. We report on a new approach to high-resolution functional and anatomical breast angiography using volumetric hand-held optoacoustic tomography, which employs light intensities safe for human use. Experiments in young healthy volunteers with fibroglandular-dominated dense breasts revealed the feasibility of rendering three-dimensional images representing vascular anatomy and functional blood oxygenation parameters at video rate. Sufficient contrast was achieved at depths beyond 2 cm within dense breasts without compromising the real-time imaging performance. The suggested solution may thus find applicability as a standalone or supplemental screening tool for early detection and follow-up of carcinomas in radiographically-dense breasts. Volumetric handheld optoacoustic tomography scanner uses safe pulses of near-infrared light to render three-dimensional images of deep vascular anatomy, blood oxygenation and breast parenchyma at video rate.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbio.201500008DOI Listing

Publication Analysis

Top Keywords

volumetric hand-held
8
hand-held optoacoustic
8
optoacoustic tomography
8
dense breasts
8
three-dimensional images
8
vascular anatomy
8
blood oxygenation
8
video rate
8
breast
5
optoacoustic angiography
4

Similar Publications

Conventional B-mode ultrasound imaging has difficulty in delineating homogeneous soft tissues with similar acoustic impedances, as the reflectivity depends on the acoustic impedance at the interface. As a quantitative imaging biomarker sensitive to alteration of biomechanical properties, speed-of-sound (SoS) holds promising potential for tissue and disease differentiation such as delineation of different breast tissue types with similar acoustic impedance. Compared to two-dimensional (2D) SoS images, three-dimensional (3D) volumetric SoS images achieved through a full-angle ultrasound scan can reveal more intricate morphological structures of tissues; however, they generally require a ring transducer.

View Article and Find Full Text PDF

Multispectral Optoacoustic Tomography Enables In Vivo Anatomical and Functional Assessment of Human Tendons.

Adv Sci (Weinh)

May 2024

Faculty of Medicine, Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, University of Zurich, Winterthurerstrasse 190, Zurich, CH-8057, Switzerland.

Tendon injuries resulting from accidents and aging are increasing globally. However, key tendon functional parameters such as microvascularity and oxygen perfusion remain inaccessible via the currently available clinical diagnostic tools, resulting in disagreements on optimal treatment options. Here, a new noninvasive method for anatomical and functional characterization of human tendons based on multispectral optoacoustic tomography (MSOT) is reported.

View Article and Find Full Text PDF

Objective evaluation of volumetric changes during breast augmentation using intraoperative three-dimensional surface imaging.

J Plast Reconstr Aesthet Surg

September 2022

Division of Hand, Plastic and Aesthetic Surgery, University Hospital, LMU Munich, Ziemssenstraße 5, Munich 80336, Germany.

Background: Breast volume estimation and implant size are crucial factors to achieve a symmetrical result in esthetic and reconstructive breast surgery. Although three-dimensional surface imaging (3DSI) has allowed for a better understanding of breast shape, size, and asymmetry during patient consultation, its use has been limited regarding intraoperative decision-making.

Objective: To validate the intraoperative use of a portable hand-held 3D surface imaging device as an objective tool to assess volumetric changes during breast augmentation surgery.

View Article and Find Full Text PDF

Three-Dimensional Mapping of Shear Wave Velocity in Human Tendon: A Proof of Concept Study.

Sensors (Basel)

February 2021

Sports Medical Research Group, Department of Orthopaedics, Balgrist University Hospital, University of Zurich, 8008 Zurich, Switzerland.

Ultrasound-based shear wave elastography (SWE) provides the means to quantify tissue mechanical properties in vivo and has proven valuable in detecting degenerative processes in tendons. Its current mode of use is for two-dimensional rendering measurements, which are highly position-dependent. We therefore propose an approach to create a volumetric reconstruction of the mechano-acoustic properties of a structure of interest based on optically tracking the ultrasound probe during free-hand measurement sweeps.

View Article and Find Full Text PDF

Purpose: To compare automated breast volumetric scanning (ABVS) with hand-held bilateral whole breast ultrasound (HHUS) prospectively in regards to patient workflow, woman preference, efficacy in lesion detection, and characterization.

Materials And Methods: Supplemental screening was performed with both ABVS and HHUS to 345 women with dense breasts and negative mammograms. Acquisition and evaluation times were recorded.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!