A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simultaneous determination of acetaminophen and dihydrocodeine in human plasma by UPLC-MS/MS: Its pharmacokinetic application. | LitMetric

An ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed and validated to determine acetaminophen (AAP) and dihydrocodeine (DHC) in human plasma simultaneously. Plasma samples were prepared using protein precipitation with acetonitrile, the two analytes and the internal standard midazolam were separated on an Acquity UPLC BEH C18 column and mass spectrometric analysis was performed using a QTrap5500 mass spectrometer coupled with an electro-spray ionization (ESI) source in the positive ion mode. The MRM transitions of m/z 151.2→110.0 and m/z 302.3→199.2 were used to quantify for AAP and DHC, respectively. The linearity of this method was found to be within the concentration range of 50-10000ng/mL for AAP, and 1-100ng/mL for DHC in human plasma, respectively. The lower limit of quantification (LLOQ) was 50ng/mL and 1ng/mL for AAP and DHC in human plasma, respectively. The relative standard deviations (RSD) of intra and inter precision were less than 10% for both AAP and DHC. The analysis time of per sample was 1.0min. The developed and validated method was successfully applied to a pharmacokinetic study of AAP (500mg) with DHC (20mg) capsule in Chinese healthy volunteers (N=20).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2015.04.031DOI Listing

Publication Analysis

Top Keywords

human plasma
16
dhc human
12
aap dhc
12
developed validated
8
aap
6
dhc
6
plasma
5
simultaneous determination
4
determination acetaminophen
4
acetaminophen dihydrocodeine
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!