An improved analytical method was developed for determining of low levels of radiostrontium in environmental freshwater samples. Emphasis was placed to the in situ pre-concentration of radiostrontium with Powdex resin in large volumes (100-300 L) of freshwater samples from many locations without using of deleterious substances such as NaOH and mineral acids. Measuring electric conductivity (EC) of water samples enabled the estimation of the amount of Powdex resin required for quantitative recovery of Sr from the large water samples in the field. The Powdex resin that adsorbed Sr was brought back to the laboratory, and Sr adsorbed in the resin was eluted by 8 M HNO3 together with Sr carrier added. Strontium was radiochemically separated by the cation exchange method for β counting after removal of most of the Ca using Ca(OH)2 precipitation. Through the procedure the Sr chemical yield was 88% on average. This analytical method was verified by analyzing 170 L of water samples with different salinity values, to which a known amount of (90)Sr was added. The detection limits of (90)Sr activities obtained using the 170 L water samples was estimated to be approximately 0.1 mBq L(-1) for a counting time of 100 min. The method was also applied to environmental samples collected from Ibaraki and Fukushima prefectures; their (90)Sr activities ranged from 0.16 to 0.93 mBq L(-)(1).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jenvrad.2015.04.011DOI Listing

Publication Analysis

Top Keywords

powdex resin
16
water samples
16
emphasis situ
8
situ pre-concentration
8
analytical method
8
freshwater samples
8
170 l water
8
90sr activities
8
samples
7
resin
5

Similar Publications

CAESIUM RETENTION CHARACTERISTICS OF KNIFC-PAN RESIN FROM RIVER WATER.

Radiat Prot Dosimetry

September 2020

Institute of Radiation Emergency Medicine, Hirosaki University, Hirosaki 036-8203, Japan.

The caesium retention characteristics of a potassium-nickel hexacyanoferrate resin in a polyacrylnitrile (KNiFC-PAN) matrix were tested in fresh water over the range of 2.5-400 mL min-1. The experimental setup used 2 mL resin and 4-L aliquots of freshwater samples.

View Article and Find Full Text PDF

An improved analytical method was developed for determining of low levels of radiostrontium in environmental freshwater samples. Emphasis was placed to the in situ pre-concentration of radiostrontium with Powdex resin in large volumes (100-300 L) of freshwater samples from many locations without using of deleterious substances such as NaOH and mineral acids. Measuring electric conductivity (EC) of water samples enabled the estimation of the amount of Powdex resin required for quantitative recovery of Sr from the large water samples in the field.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!