A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Upper extremity 3-dimensional reachable workspace assessment in amyotrophic lateral sclerosis by Kinect sensor. | LitMetric

Introduction: Reachable workspace is a measure that provides clinically meaningful information regarding arm function. In this study, a Kinect sensor was used to determine the spectrum of 3-dimensional reachable workspace encountered in a cross-sectional cohort of individuals with amyotrophic lateral sclerosis (ALS).

Methods: Bilateral 3D reachable workspace was recorded from 10 subjects with ALS and 17 healthy controls. The data were normalized by each individual's arm length to obtain a reachable workspace relative surface area (RSA). Concurrent validity was assessed by correlation with scoring on the ALS Functional Rating Score-revised (ALSFRSr).

Results: The Kinect-measured reachable workspace RSA differed significantly between the ALS and control subjects (0.579 ± 0.226 vs. 0.786 ± 0.069; P < 0.001). The RSA demonstrated correlation with ALSFRSr upper extremity items (Spearman correlation ρ = 0.569; P = 0.009). With worsening upper extremity function, as categorized by the ALSFRSr, the reachable workspace also decreased progressively.

Conclusions: This study demonstrates the feasibility and potential of using a novel Kinect-based reachable workspace outcome measure in ALS.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4770889PMC
http://dx.doi.org/10.1002/mus.24703DOI Listing

Publication Analysis

Top Keywords

reachable workspace
32
upper extremity
12
reachable
8
3-dimensional reachable
8
workspace
8
amyotrophic lateral
8
lateral sclerosis
8
kinect sensor
8
extremity 3-dimensional
4
workspace assessment
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!