Stomatopod crustaceans employ unique ultraviolet (UV) optical filters in order to tune the spectral sensitivities of their UV-sensitive photoreceptors. In the stomatopod species Neogonodactylus oerstedii, we previously found four filter types, produced by five distinct mycosporine-like amino acid pigments in the crystalline cones of their specialized midband ommatidial facets. This UV-spectral tuning array produces receptors with at least six distinct spectral sensitivities, despite expressing only two visual pigments. Here, we present a broad survey of these UV filters across the stomatopod order, examining their spectral absorption properties in 21 species from seven families in four superfamilies. We found that UV filters are present in three of the four superfamilies, and evolutionary character reconstruction implies that at least one class of UV filter was present in the ancestor of all modern stomatopods. Additionally, postlarval stomatopods were observed to produce the UV filters simultaneously alongside development of the adult eye. The absorbance properties of the filters are consistent within a species; however, between species we found a great deal of diversity, both in the number of filters and in their spectral absorbance characteristics. This diversity correlates with the habitat depth ranges of these species, suggesting that species living in shallow, UV-rich environments may tune their UV spectral sensitivities more aggressively. We also found additional, previously unrecognized UV filter types in the crystalline cones of the peripheral eye regions of some species, indicating the possibility for even greater stomatopod visual complexity than previously thought.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1242/jeb.122036 | DOI Listing |
Nano Lett
January 2025
School of Advanced Materials, Shenzhen Graduate School, Peking University, Shenzhen 518055, P. R. China.
The high responsivity and broad spectral sensitivity of organic photodetectors (OPDs) present a bright future of commercialization. However, the relatively high dark current density still limits its development. Herein, two novel nonpolar p-type conjugated small molecules, NSN and NSSN, are synthesized as interface layers to enhance the performance of the OPDs, which not only can tune energy alignments and increase the reverse charge injection barrier but also can reduce the interfacial trap density.
View Article and Find Full Text PDFRapid Commun Mass Spectrom
April 2025
State Key Laboratory of Environmental and Biological Analysis, Department of Chemistry, Hong Kong Baptist University, Hong Kong SAR, China.
Rational: People are widely exposed to parabens in their daily life, but parabens are endocrine disrupting chemicals that pose a threat to human health. Therefore, establishing a rapid screening method to enhance monitoring of parabens is necessary. Herein, a covalent organic framework (COF) nanofilm-assisted laser desorption ionization mass spectrometry (LDI-MS) method was established to screen parabens in personal care products (PCPs).
View Article and Find Full Text PDFMagn Reson Med
January 2025
National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland, USA.
Purpose: Two-shot γ-aminobutyric acid (GABA) difference editing techniques have been used widely to detect the GABA H4 resonance at 3.01 ppm. Here, we introduce a single-shot method for detecting the full GABA H2 resonance signal, which avoids contamination from the coedited M macromolecules.
View Article and Find Full Text PDFAnal Chem
January 2025
College of Chemistry, Jilin Province Research Center for Engineering and Technology of Spectral Analytical Instruments, Jilin University, Qianjin Street 2699, Changchun 130012, China.
Vanin-1 is a pantetheine hydrolase that plays a key role in inflammatory diseases. Effective tools for noninvasive, real-time monitoring of Vanin-1 are lacking, largely due to background fluorescence interference in existing probes. To address this issue, we developed a dual-modal fluorescent and colorimetric probe, MB-Van1, to detect Vanin-1 with high sensitivity and selectivity.
View Article and Find Full Text PDFAnesthesiology
January 2025
Department of Anesthesiology, Brigham and Women's Hospital and Harvard Medical School, Boston MA, USA.
Introduction: Accurate prognostication in comatose survivors of cardiac arrest is a challenging and high-stakes endeavor. We sought to determine whether internal EEG subparameters extracted by the Bispectral Index (BIS) monitor, a device commonly used to estimate depth-of-anesthesia intraoperatively, could be repurposed to predict recovery of consciousness after cardiac arrest.
Methods: In this retrospective cohort study, we trained a 3-layer neural network to predict recovery of consciousness to the point of command following versus not based on 48 hours of continuous EEG recordings in 315 comatose patients admitted to a single US academic medical center after cardiac arrest (Derivation cohort: N=181; Validation cohort: N=134).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!