The latest determination of the Avogadro constant, carried out by counting the atoms in a pure silicon crystal highly enriched in (28)Si, reached the target 2 × 10(-8) relative uncertainty required for the redefinition of the kilogram based on the Planck constant. The knowledge of the isotopic composition of the enriched silicon material is central; it is measured by isotope dilution mass spectrometry. In this work, an independent estimate of the (30)Si mole fraction was obtained by applying a relative measurement protocol based on Instrumental Neutron Activation Analysis. The amount of (30)Si isotope was determined by counting the 1266.1 keV γ-photons emitted during the radioactive decay of the radioisotope (31)Si produced via the neutron capture reaction (30)Si(n,γ)(31)Si. The x((30)Si) = 1.043(19) × 10(-6) mol mol(-1) is consistent with the value currently adopted by the International Avogadro Coordination.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.5b00878DOI Listing

Publication Analysis

Top Keywords

30si mole
8
mole fraction
8
silicon material
8
highly enriched
8
enriched 28si
8
instrumental neutron
8
neutron activation
8
activation analysis
8
fraction silicon
4
material highly
4

Similar Publications

The use of new silicon single crystals highly enriched in Si recently produced for the upcoming redetermination of the Avogadro constant requires knowledge of their molar masses. The isotopic composition data are collected independently in different laboratories but all using the virtual element technique with multicollector inductively coupled plasma mass spectrometers. In this framework, the comparison of the results with an independent measurement of the amount of at least one of the depleted isotopes is useful to limit hidden systematic errors.

View Article and Find Full Text PDF

The latest determination of the Avogadro constant, carried out by counting the atoms in a pure silicon crystal highly enriched in (28)Si, reached the target 2 × 10(-8) relative uncertainty required for the redefinition of the kilogram based on the Planck constant. The knowledge of the isotopic composition of the enriched silicon material is central; it is measured by isotope dilution mass spectrometry. In this work, an independent estimate of the (30)Si mole fraction was obtained by applying a relative measurement protocol based on Instrumental Neutron Activation Analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!