Background: The reverse total shoulder arthroplasty (RTSA) has been used in the treatment of complex shoulder problems. The incidence of aseptic loosening of the humeral component has not been previously reported.
Methods: This is a multicenter, retrospective, blinded, case-control radiographic review of 292 patients to determine the rate of humeral stem loosening. There were 177 cemented and 115 press-fit humeral components. Radiographs were critiqued for radiolucent lines adjacent to the humeral stem based on the method described by Gruen et al.
Results: The overall rate of loosening was 0.74%. No radiographic loosening occurred in the press-fit group (115 stems). In the cemented group (177 stems), 2 shoulders (1.18%) were identified with radiographically loose stems. No loosening occurred in the press-fit group. No statistically significant difference was found in humeral stem loosening when the press-fit group and the cemented group were compared (P = .198).
Discussion: Our study indicates the cemented or press-fit RTSA system will result in a low incidence of radiolucent lines and radiographic loosening. Compared with historical survivorship of conventional anatomic total shoulder arthroplasty, RTSA shows a lower rate of radiographic stem loosening at a mean of 38.46 months.
Conclusions: The RTSA has a low incidence of humeral stem loosening at midterm. These results underscore the importance of careful selection of patients to provide the benefits of this surgical technique. Press-fit fixation may provide a lower risk to stem loosening.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jse.2015.02.007 | DOI Listing |
J Clin Med
January 2025
Shoulder and Elbow Surgery, Schulthess Clinic Zürich, 8008 Zürich, Switzerland.
: Classical reverse shoulder arthroplasty (RSA) with a high neck-shaft angle (NSA) of 155° has shown satisfactory outcomes. However, newer RSA designs aim to improve results by modifying the stem design. This study evaluates the 5-year outcomes of a stem design featuring a rectangular metadiaphyseal fixation and a 135° NSA.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Orthopaedic Surgery, Chosun University Hospital, 365 Pilmundae-ro, Dong-gu, Gwangju 61453, Republic of Korea.
Managing periprosthetic femoral fractures is challenging, particularly in osteoporotic patients with fragile bones. Revision with a long stem is commonly considered but may fail to provide adequate fixation and stability in fragile bones. A novel approach using sandwiched strut allografts and controlled bone crushing with robust cable fixation can offer mechanical support and provide secondary stability to the loosened femoral stem and can be considered a treatment option for low-demand patients.
View Article and Find Full Text PDFBiomimetics (Basel)
January 2025
Center for Biomedical Technology, Universidad Politécnica de Madrid, Pozuelo de Alarcón, 28223 Madrid, Spain.
Under benign conditions, bone tissue can regenerate itself without external intervention. However, this regenerative capacity can be compromised by various factors, most importantly related with the extent of the injury. Critical-sized defects, exceeding the body's natural healing ability, demand the use of temporary or permanent devices like artificial joints or bone substitutes.
View Article and Find Full Text PDFWorld J Orthop
January 2025
Department of Orthopaedics, Indira Gandhi Medical College and Hospital, Shimla 171001, Himāchal Pradesh, India.
Background: Total hip arthroplasty (THA) has increased along with an increasing demand for improved quality of life. Combined with prolonged life expectancy, the number of revision surgeries is expected to increase. Stress shielding is a significant issue with traditional femoral stems used in THA, making revision surgeries particularly challenging in younger patients.
View Article and Find Full Text PDFSICOT J
January 2025
Department of Orthopedic Surgery and Sport Medicine, Croix-Rousse Hospital, FIFA Medical Center of Excellence, 69004 Lyon, France - Université de Lyon, Université Claude Bernard Lyon 1, IFSTTAR, LBMC UMR_T9406, 69622 Lyon, France.
Introduction: Revision Total Knee Arthroplasty (RTKA) is complex, and induced bone loss might endanger implant fixation and joint stability. Intramedullary stems improve fixation throughout stress redistribution. The current study aims to compare the performance of short tibial stems with long tibial stems, investigating their intermediate-term radiographic and survival outcomes in RTKA.