Objectives: Quantitative assessment of left ventricular (LV) functional parameters in cardiac MR requires time-consuming contour tracing across multiple short axis images. This study assesses global LV functional parameters using 3-slice segmentation on steady state free precision (SSFP) cine short axis images and compares the results with conventional multi-slice segmentation of LV.

Methods: Data were collected from 61 patients who underwent cardiac MRI for various clinical indications. Semi-automated cardiac MR software was used to trace LV contours both at multiple slices from base to apex as well as just 3 slices (base, mid, and apical) by two readers. Left ventricular ejection fraction (LVEF), LV volumes, and LV mass were calculated using both methods.

Results: Bland-Altman plot revealed narrow limits of agreement (-4.4% to 5.1%) between LVEF obtained by the two methods. Bland-Altman analysis showed slightly wider limits of agreement between end-diastolic volumes (-5.0 to 12.0%; -3.9 to 8.5 ml/m(2)), end-systolic volumes (-10.9 to 14.7%; -4.1 to 6.5 ml/m(2)), and LV mass (-5.2 to 12.7%; -4.8 to 10.2g/m(2)) obtained by the two methods. There was a small mean difference between LV volumes and LV mass obtained using multi-slice and 3-slice segmentation. No statistically significant difference existed between the LV parameters obtained by the two readers using 3-slice segmentation (p>0.05). Multi-slice assessment required approximately 15 min per study while 3-slice assessment required less than 5 min.

Conclusions: 3-slice segmentation of the left ventricle at basal, mid, and apical levels on cine SSFP short axis images can provide rapid and reliable assessment of LVEF with good reproducibility. The 3-slice method also provides a reasonable estimate of the LV volumes and LV mass.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2015.03.019DOI Listing

Publication Analysis

Top Keywords

3-slice segmentation
20
short axis
16
axis images
16
left ventricular
12
volumes mass
12
quantitative assessment
8
assessment left
8
functional parameters
8
slices base
8
mid apical
8

Similar Publications

Introduction: Current practice to obtain left ventricular (LV) native and post-contrast T1 and T2 comprises single-slice readouts with multiple breath-holds (BHs). We propose a multi-slice parallel-imaging approach with a 72-channel receive-array to reduce BHs and demonstrate this in healthy subjects and hypertrophic cardiomyopathy (HCM) patients.

Methods: A T1/T2 phantom was scanned at 3 T using a 16-channel and a novel 72-channel coil to assess the impact of different coils and acceleration factors on relaxation times.

View Article and Find Full Text PDF

Background: Body composition (BC) is an important factor in determining the risk of type 2-diabetes and cardiovascular disease. Computed tomography (CT) is a useful imaging technique for studying BC, however manual segmentation of CT images is time-consuming and subjective. The purpose of this study is to develop and evaluate fully automated segmentation techniques applicable to a 3-slice CT imaging protocol, consisting of single slices at the level of the liver, abdomen, and thigh, allowing detailed analysis of numerous tissues and organs.

View Article and Find Full Text PDF

Epicardial adipose tissue volume (EAT) has been linked to coronary artery disease and the risk of major adverse cardiac events. As manual quantification of EAT is time-consuming, requires specialized training, and is prone to human error, we developed a deep learning method (DeepFat) for the automatic assessment of EAT on non-contrast low-dose CT calcium score images. Our DeepFat intuitively segmented the tissue enclosed by the pericardial sac on axial slices, using two preprocessing steps.

View Article and Find Full Text PDF

Purpose: Timely, accurate and reliable assessment of fetal brain development is essential to reduce short and long-term risks to fetus and mother. Fetal MRI is increasingly used for fetal brain assessment. Three key biometric linear measurements important for fetal brain evaluation are cerebral biparietal diameter (CBD), bone biparietal diameter (BBD), and trans-cerebellum diameter (TCD), obtained manually by expert radiologists on reference slices, which is time consuming and prone to human error.

View Article and Find Full Text PDF

This study evaluates the accuracy of a computer-aided detection (CAD) application for pulmonary nodular lesions (PNL) in computed tomography (CT) scans, the ClearReadCT (Riverain Technologies). The study was retrospective for 106 biopsied PNLs from 100 patients. Seventy-five scans were Contrast-Enhanced (CECT) and 25 received no enhancer (NECT).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!