Mechanics of mitral valve edge-to-edge-repair and MitraClip procedure.

J Long Term Eff Med Implants

Cardiovascular Mechanics Laboratory, Department of Mechanical Engineering, Texas Tech University, Lubbock, Texas.

Published: December 2016

The edge-to-edge repair (ETER) technique has been used as a stand-alone procedure, or as a secondary procedure with ring annuloplasty for degenerative, functional mitral regurgitation, or for mitral regurgitation of other kinds of valvular etiologies. The percutaneous MitraClip technique based on ETER has been used in patients who are inoperable or at high surgical risk. However, adverse events such as residual mitral regurgitation, and clip detachment or fracture indicate that the mechanics underlying these procedures is not well understood. Therefore, current studies on mitral valve functionality and mechanics related to the ETER and MitraClip procedures are reviewed to improve the efficacy and safety of both procedures. Extensive in vivo, in vitro, and in silico studies related to ETER and MitraClip procedures along with MitraClip clinical trial results are presented and discussed herein. The ETER suture force and the mitral valve tissue mechanics and hemodynamics of each procedure are discussed. A quantitative understanding of the interplay of mitral valve components and as to biological response to the procedures remains challenging. Based on mitral valve mechanics, ETER or MitraClip therapy can be optimized to enhance repair efficacy and durability.

Download full-text PDF

Source
http://dx.doi.org/10.1615/jlongtermeffmedimplants.2015011729DOI Listing

Publication Analysis

Top Keywords

mitral valve
20
mitral regurgitation
12
eter mitraclip
12
mechanics eter
8
mitraclip procedures
8
mitral
7
mitraclip
6
eter
6
mechanics
5
valve
5

Similar Publications

Background: Left atrial dissection is a rare and occasionally fatal complication of cardiac surgery and is defined as the creation of a false chamber through a tear in the mitral valve annulus extending into the left atrial wall. Some patients are asymptomatic, while others present with various symptoms, such as chest pain, dyspnea, and even cardiac arrest. Although there is no established management for left atrial dissection, surgery should be considered in patients with hemodynamic disruption.

View Article and Find Full Text PDF

Objectives: Transcatheter edge-to-edge repair (TEER) is an alternative for patients with severe degenerative mitral regurgitation (MR). The objective of this study was to compare the outcomes of surgery and TEER in older patients with degenerative MR patients using real life data.

Methods: Consecutives older patients (≥ 65 years-old), with severe symptomatic, degenerative MR requiring surgery or TEER between 2013 and 2023 were included.

View Article and Find Full Text PDF

Purpose: Pre-procedural imaging is critical for transcatheter mitral valve repair planning in patients with mitral valve disease. As differences among various measurement techniques for valve evaluation are still poorly understood, we sought to assess the intra- and interobserver agreement of complex measurements derived from a prototype mitral evaluation tool (Siemens) and a commercially available tool (CVI42) using both saddle- and D-shaped mitral annulus techniques.

Materials And Methods: Multiphasic cardiac computed tomography angiography data were loaded into each software.

View Article and Find Full Text PDF

Post-operative new-onset atrial fibrillation (POAF) is a possible complication following cardiac surgery. Digoxin is a drug with positive inotropic and negative chronotropic effects and is listed among antiarrhythmic drugs that can be prescribed in dogs with atrial fibrillation. This report aims at describing the use of digoxin in two dogs with persistent POAF after mitral valve repair.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?